SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:3d493952-f01c-4460-8557-287643af0086"
 

Sökning: id:"swepub:oai:research.chalmers.se:3d493952-f01c-4460-8557-287643af0086" > Hit detection in se...

Hit detection in serial femtosecond crystallography using X-ray spectroscopy of plasma emission

Jonsson, H. O. (författare)
Uppsala universitet,Uppsala University
Caleman, C. (författare)
Uppsala universitet,Uppsala University,Deutsches Elektronen-Synchrotron (DESY)
Andreasson, Jakob, 1975 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Timneanu, N. (författare)
Uppsala universitet,Uppsala University
visa färre...
 (creator_code:org_t)
2017-10-13
2017
Engelska.
Ingår i: IUCrJ. - : International Union of Crystallography (IUCr). - 2052-2525. ; 4, s. 778-784
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Serial femtosecond crystallography is an emerging and promising method for determining protein structures, making use of the ultrafast and bright X-ray pulses from X-ray free-electron lasers. The upcoming X-ray laser sources will produce well above 1000 pulses per second and will pose a new challenge: how to quickly determine successful crystal hits and avoid a high-rate data deluge. Proposed here is a hit-finding scheme based on detecting photons from plasma emission after the sample has been intercepted by the X-ray laser. Plasma emission spectra are simulated for systems exposed to high-intensity femtosecond pulses, for both protein crystals and the liquid carrier systems that are used for sample delivery. The thermal radiation from the glowing plasma gives a strong background in the XUV region that depends on the intensity of the pulse, around the emission lines from light elements (carbon, nitrogen, oxygen). Sample hits can be reliably distinguished from the carrier liquid based on the characteristic emission lines from heavier elements present only in the sample, such as sulfur. For buffer systems with sulfur present, selenomethionine substitution is suggested, where the selenium emission lines could be used both as an indication of a hit and as an aid in phasing and structural reconstruction of the protein.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

serial femtosecond crystallography
hit detection
protein structure
plasma emission spectra

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • IUCrJ (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Jonsson, H. O.
Caleman, C.
Andreasson, Jako ...
Timneanu, N.
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
och Atom och molekyl ...
Artiklar i publikationen
IUCrJ
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy