SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:3ddf8b27-9154-42be-92b8-b0c7592dbd96"
 

Sökning: id:"swepub:oai:research.chalmers.se:3ddf8b27-9154-42be-92b8-b0c7592dbd96" > Norovirus Dynamics ...

Norovirus Dynamics in Wastewater Discharges and in the Recipient Drinking Water Source: Long-Term Monitoring and Hydrodynamic Modeling

Dienus, Olaf (författare)
Linköpings universitet,Avdelningen för mikrobiologi och molekylär medicin,Medicinska fakulteten,Ryhov County Hospital, Medical Services, Clinical Microbiology, Jönköping, Sweden;Linköping University, Department of Clinical and Experimental Medicine, Medical Microbiology, Linköping, Sweden,Linköping University,Länssjukhuset Ryhov,County Hospital Ryhov
Sokolova, Ekaterina, 1986 (författare)
Chalmers tekniska högskola,Chalmers University of Technology,Chalmers University of Technology, Department of Civil and Environmental Engineering, Water Environment Technology, Gothenburg, Sweden
Nyström, Fredrik (författare)
Linköpings universitet,Medicinska fakulteten,Avdelningen för neuro- och inflammationsvetenskap,Ryhov County Hospital, Sweden; Luleå University of Technology, Sweden,Ryhov County Hospital, Medical Services, Clinical Microbiology, Jönköping, Sweden; Linköping University, Department of Clinical and Experimental Medicine, Medical Microbiology, Linköping, Sweden,Länssjukhuset Ryhov,County Hospital Ryhov,Luleå tekniska universitet (LTU),Luleå University of Technology (LTU),Linköping University
visa fler...
Matussek, Andreas (författare)
Länssjukhuset Ryhov,County Hospital Ryhov,Ryhov County Hospital, Medical Services, Clinical Microbiology, Jönköping, Sweden
Lofgren, S. (författare)
Länssjukhuset Ryhov,County Hospital Ryhov,Ryhov County Hospital, Medical Services, Clinical Microbiology, Jönköping, Sweden
Blom, Lena B, 1966 (författare)
Chalmers tekniska högskola,Chalmers University of Technology,Chalmers University of Technology, Department of Civil and Environmental Engineering, Water Environment Technology, Gothenburg, Sweden;City of Gothenburg, Department of Sustainable Waste and Water, Angered, Sweden
Pettersson, Thomas, 1966 (författare)
Chalmers tekniska högskola,Chalmers University of Technology,Chalmers University of Technology, Department of Civil and Environmental Engineering, Water Environment Technology, Gothenburg, Sweden
Lindgren, Per-Eric (författare)
Linköpings universitet,Avdelningen för mikrobiologi och molekylär medicin,Medicinska fakulteten,Ryhov County Hospital, Medical Services, Clinical Microbiology, Jönköping, Sweden;Linköping University, Department of Clinical and Experimental Medicine, Medical Microbiology, Linköping, Sweden,Linköping University,Länssjukhuset Ryhov,County Hospital Ryhov
visa färre...
 (creator_code:org_t)
2016-10-04
2016
Engelska.
Ingår i: Environmental Science & Technology. - : American Chemical Society (ACS). - 0013-936X .- 1520-5851. ; 50:20, s. 10851-10858
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Norovirus (NoV) that enters drinking water sources with wastewater discharges is a common cause of waterborne outbreaks. The impact of wastewater treatment plants (WWTPs) on the river Gota alv (Sweden) was studied using monitoring and hydrodynamic modeling. The concentrations of NoV genogroups (GG) I and II in samples collected at WWTPs and drinking water intakes (source water) during one year were quantified using duplex real-time reverse-transcription polymerase chain reaction. The mean (standard deviation) NoV GGI and GGII genome concentrations were 6.2 (1.4) and 6.8 (1.8) in incoming wastewater and 5.3 (1.4) and 5.9 (1.4) log(10) genome equivalents (g.e.) L-1 in treated wastewater, respectively. The reduction at the WWTPs varied between 0.4 and 1.1 log(10) units. In source water, the concentration ranged from below the detection limit to 3.8 log(10) g.e. L-1. NoV GGII was detected in both wastewater and source water more frequently during the cold than the warm period of the year. The spread of NoV in the river was simulated using a three-dimensional hydrodynamic model. The modeling results indicated that the NoV GGI and GGII genome concentrations in source water may occasionally be up to 2.8 and 1.9 log(10) units higher, respectively, than the concentrations measured during the monitoring project.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Miljöbioteknik -- Vattenbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Biotechnology -- Water Treatment (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Vattenteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Water Engineering (hsv//eng)

Nyckelord

MICROBIAL RISK-ASSESSMENT
ENTERIC VIRUSES
Environmental
RT-PCR
TREATMENT-PLANT
Environmental Sciences
NORWALK-LIKE VIRUSES
GASTROENTERITIS
Engineering
PERSISTENCE
INDICATOR BACTERIA
SURFACE-WATER
GENOGROUP-I

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy