SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:3fcf3e4e-3b20-49c9-b16c-4eaef27e0e90"
 

Sökning: id:"swepub:oai:research.chalmers.se:3fcf3e4e-3b20-49c9-b16c-4eaef27e0e90" > Combining direct gr...

Combining direct ground cooling with ground-source heat pumps and district heating: Energy and economic analysis

Arghand, Taha, 1982 (författare)
Chalmers University of Technology
Javed, Saqib, 1978 (författare)
Lund University,Lunds universitet,Avdelningen för Installations- och klimatiseringslära,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Building Services,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
Dalenbäck, Jan-Olof, 1954 (författare)
Chalmers University of Technology
 (creator_code:org_t)
Elsevier BV, 2023
2023
Engelska.
Ingår i: Energy. - : Elsevier BV. - 0360-5442. ; 270
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Direct ground cooling (DGC) is a method used in cold climates to provide cooling to buildings without the use of any mechanical refrigeration. When DGC is utilized for providing cooling, ground-source heat pumps (GSHPs) and district heating (DH) are the two commonly used technologies for providing heating to the buildings. This article investigates the coupling of DGC with GSHPs and DH in terms of purchased energy and lifecycle costs. An office building equipped with active chilled beams for cooling and radiators for heating is used as a reference. Six cases based on different combinations of building envelope characteristics and thus different building heating and cooling loads are considered. The results show that using DGC-DH significantly reduces the amount of purchased electricity. However, the total energy cost is lower when DGC-GSHP is used. In addition, the DGC-GSHP can be more viable when the ground loads are well balanced. Investment costs, including borehole installation and equipment costs, are lower for the DGC-DH in the majority of the investigated cases. The lifecycle cost is lower for the DGC-DH in most of the investigated cases due to lower equipment costs.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Energisystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Energy Systems (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Nyckelord

Ground-source heat pump (GSHP)
High-temperature cooling
Lifecycle cost (LCC)
Energy efficiency
District heating
Direct ground cooling
Direct ground cooling
District heating
Energy efficiency
Ground-source heat pump (GSHP)
High-temperature cooling
Lifecycle cost (LCC)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Energy (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Arghand, Taha, 1 ...
Javed, Saqib, 19 ...
Dalenbäck, Jan-O ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Naturresurstekni ...
och Energisystem
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
och Husbyggnad
Artiklar i publikationen
Energy
Av lärosätet
Chalmers tekniska högskola
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy