Bone conducted sound transmission for communication systems

Reinfeldt, Sabine, 1978 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
 (creator_code:org_t)
2006
Engelska.
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Bone conducted (BC) sound is vibrations in the skull bone that are transmitted to the cochlea and perceived as sound, originating from a sound field or a vibration transducer. This transmission path can be advantageous for communication systems in some situations, e.g. extremely noisy environments, where it is required to protect the hearing with hearing protection devices in the ear canals; such devices may prevent the use of ordinary communication systems. Moreover, if a BC microphone that records one's own voice at the skull bone is used, an advantageous signal-to-noise situation can be achieved compared with an ordinary AC microphone in front of the mouth. The requirements and possibilities of using BC communication systems are investigated in this thesis.It was found that the possible improvement in signal-to-noise ratio of using a BC microphone, instead of an ordinary AC microphone, could be as much as 40 to 60 dB. Furthermore, due to the occlusion effect, the perception of the BC sound is affected at low frequencies when using hearing protection devices, such as earplugs and earmuffs. This reduces the effectiveness of hearing protection devices at low frequencies. By devising an acoustical model of the occlusion effect, the low-frequency increase from occluding the ear canal could be estimated. The estimations were compared with measured occlusion effect data allowing fitting of the model parameters. The model is able to predict occlusion effects of different types and at different positions with a typical error of less than 5 dB. Also, perception data was compared with ear canal sound pressures when the BC stimulation was at three different positions: ipsilateral mastoid, forehead, and contralateral mastoid. This provided information on the amount of sound that reaches the cochleae from the stimulation position. The results also showed that the ear canal sound pressure is a good proxy of the relative BC perception at frequencies above 800 Hz.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

bone conduction
sound field hearing
occlusion effect
transcranial transmission
communication system
bone conduction microphone
hearing protection devices
hearing

Publikations- och innehållstyp

lic (ämneskategori)
vet (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Reinfeldt, Sabin ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy