SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:47d287cd-f789-4a9b-93c1-1d9e2ce22847"
 

Sökning: id:"swepub:oai:research.chalmers.se:47d287cd-f789-4a9b-93c1-1d9e2ce22847" > Progress of combust...

Progress of combustion in the furnace of a circulating fluidised bed boiler

Lyngfelt, Anders, 1955 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Åmand, Lars-Erik, 1957 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Leckner, Bo G, 1936 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
 (creator_code:org_t)
1996
1996
Engelska.
Ingår i: Twenty-sixth Symposium (International) on Combustion. ; , s. 3253-3259
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Gas concentrations were measured in the combustion chamber of a circulating fluidized bed boiler(FBB ). Sieved fractions of solid material sampled at different heights were analyzed for combustible matter. Together with the bulk density profile obtained from pressure drop measurements, these data were used to obtain the distribution of combustible matter in the combustion chamber. High concentrations of combustible gases and low concentrations of oxygen Were found in the bottom part, indicating that the bed material to a large extent is subject to reducing conditions. From the gas concentration profile, the degree of combustion/fuel conversion versus boiler height was deduced. This procedure, however, involves a major error since measured concentrations gin, a misrepresentation of the concentrations of the gas flow. This is explained by a through flow of gas through bubbles or voids in the bottom bed with high velocity and high concentration of oxygen. A correction for the hn1ass flow was attempted, which increases the 02 concentration in the lowest position from 2.5 to 11%. This correction compared favorably with the fuel conversion versus height, derived from the distribution of solid combustibles (char) in the combustion chamber. The results show that the concentrations measured in the bottom part of the combustion chamber do not represent the flow and cannot, accordingly, be directly used in mass balanees. This misrepresentation has consequences for the interpretation of gas measurements in the bottom part of FBBs.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Annan naturresursteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Other Environmental Engineering (hsv//eng)

Nyckelord

nitrous oxide emissions
Fluidized bed combustion
N2O
reversed air staging

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Lyngfelt, Anders ...
Åmand, Lars-Erik ...
Leckner, Bo G, 1 ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Kemiteknik
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Naturresurstekni ...
och Annan naturresur ...
Artiklar i publikationen
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy