SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:4d161203-8a22-4175-8cc9-883a7edc9dc5"
 

Sökning: id:"swepub:oai:research.chalmers.se:4d161203-8a22-4175-8cc9-883a7edc9dc5" > The heat transfer p...

The heat transfer potential of compressor vanes on a hydrogen fueled turbofan engine

Capitao Patrao, Alexandre, 1988 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Jonsson, Isak, 1990 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Xisto, Carlos, 1984 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Lundbladh, Anders, 1964 (författare)
GKN Aerospace Sweden AB,Chalmers tekniska högskola,Chalmers University of Technology
Lejon, Marcus, 1986 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Grönstedt, Tomas, 1970 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: Applied Thermal Engineering. - 1359-4311. ; 236
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Hydrogen is a promising fuel for future aviation due to its CO2-free combustion. In addition, its excellent cooling properties as it is heated from cryogenic conditions to the appropriate combustion temperatures provides a multitude of opportunities. This paper investigates the heat transfer potential of stator surfaces in a modern high-speed low-pressure compressor by incorporating cooling channels within the stator vane surfaces, where hydrogen is allowed to flow and cool the engine core air. Computational Fluid Dynamics simulations were carried out to assess the aerothermal performance of this cooled compressor and were compared to heat transfer correlations. A core air temperature drop of 9.5 K was observed for this cooling channel design while being relatively insensitive to the thermal conductivity of the vane and cooling channel wall thickness. The thermal resistance was dominated by the air-side convective heat transfer, and more surface area on the air-side would therefore be required in order to increase overall heat flow. While good agreement with established heat transfer correlations was found for both turbulent and transitional flow, the correlation for the transitional case yielded decent accuracy only as long as the flow remains attached, and while transition was dominated by the bypass mode. A system level analysis, indicated a limited but favorable impact at engine performance level, amounting to a specific fuel consumption improvement of up to 0.8 % in cruise and an estimated reduction of 3.6 % in cruise NOx. The results clearly show that, although it is possible to achieve high heat transfer rate per unit area in compressor vanes, the impact on cycle performance is constrained by the limited available wetted area in the low-pressure compressor.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Rymd- och flygteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Aerospace Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Farkostteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Vehicle Engineering (hsv//eng)

Nyckelord

Emissions
Hydrogen
CFD
Compressor
Cryogenics
Heat transfer

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy