SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:4f036160-2239-4f6d-b8a8-d3c42bce6037"
 

Sökning: id:"swepub:oai:research.chalmers.se:4f036160-2239-4f6d-b8a8-d3c42bce6037" > Optical response of...

Optical response of a titanium-based cold-electron bolometer

Otto, Ernst, 1971 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Tarasov, Mikhail, 1954 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Grimes, P. K. (författare)
University Of Oxford,Smithsonian Astrophysical Observatory
visa fler...
Chekushkin, Artem, 1991 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Kuzmin, Leonid, 1946 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Yassin, G. (författare)
University Of Oxford
visa färre...
 (creator_code:org_t)
2013-07-04
2013
Engelska.
Ingår i: Superconductor Science and Technology. - : IOP Publishing. - 0953-2048 .- 1361-6668. ; 26:8
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We present experimental results on the testing of cold-electron bolometer (CEB) detectors comprised of a thin Ti film absorber and two SIN junctions integrated with a planar antenna. The CEB performance was tested in a He-3 sorption cryostat HELIOX-AC-V at bath temperatures of 280-305 mK. The optical response was measured using the hot/cold load method by flipping a Cu reflector opposite a blackbody surface inside a 3 K shield and using a thermal source with variable temperature. In the first experiment, the detector chip was mounted in an optical sample-holder whose aperture was switched towards or away from a blackbody source changing the incident radiation temperature from 3 K to 270 mK. As a result, we measured the optical response to a 3 K/270 mK radiation temperature change. The measured voltage response value for the detector integrated in a double-dipole antenna was Delta V-out = 120 mu V. This corresponds to a noise equivalent power of NEP = V-n/(dV/dP) = 3.5 x 10(-17) W Hz(-1/2), where dV/dP is the voltage to power response obtained from the incoming power estimation based on the Planck formula.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy