SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:5873d500-d928-4cc5-a05b-837a1e4a5f1d"
 

Sökning: id:"swepub:oai:research.chalmers.se:5873d500-d928-4cc5-a05b-837a1e4a5f1d" > Finline-integrated ...

Finline-integrated cold electron bolometer

Otto, Ernst, 1971 (författare)
University Of Oxford
Tarasov, Mikhail, 1954 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Grimes, P. K. (författare)
University Of Oxford
visa fler...
Kaurova, Natalia (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Kuusisto, Hannes, 1987 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Kuzmin, Leonid, 1946 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Yassin, G. (författare)
University Of Oxford
visa färre...
 (creator_code:org_t)
ISBN 9780819482310
SPIE, 2010
2010
Engelska.
Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE. - 0277-786X .- 1996-756X. - 9780819482310 ; 7741
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • The Cold-Electron Bolometer (CEB) is a sensitive millimetre-wave detector which is easy to integrate with superconducting planar circuits. CEB detectors have other important features such as high saturation power and very fast response. We have fabricated and tested CEB detectors integrated across the slot of a unilateral finline on a silicon substrate. Bolometers were fabricated using two fabrication methods: e-beam direct-write trilayer technology and an advanced shadow mask evaporation technique. The CEB performance was tested in a He3 sorption cryostat at a bath temperature of 280mK. DC I-V curves and temperature responses were measured in a current bias mode, and preliminary measurements of the optical response were made using an IMPATT diode operating at 110GHz. These tests were conducted by coupling power directly into the finline chip, without the use of waveguide or feedhorns. For the devices fabricated in standard direct-write technology, the bolometer dark electrical noise equivalent power is estimated to be about 5×10-16W/ √Hz, while the dark NEP value for the shadow mask evaporation technique devices is estimated to be as low as 3×10-17W/√Hz.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
vet (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy