SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:61e15b1b-f696-46fd-ad5b-5ff3e0cbeedd"
 

Sökning: id:"swepub:oai:research.chalmers.se:61e15b1b-f696-46fd-ad5b-5ff3e0cbeedd" > A study on the rela...

A study on the relationship between energy performance and IEQ parameters in school buildings

Cabovska, Blanka, 1990 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Teli, Despoina, 1980 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Dalenbäck, Jan-Olof, 1954 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Langer, Sarka, 1960 (författare)
Chalmers tekniska högskola,Chalmers University of Technology,IVL Svenska Miljöinstitutet AB,IVL Swedish Environmental Research Institute
Ekberg, Lars, 1962 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
2021-03-29
2021
Engelska.
Ingår i: E3S Web of Conferences. - : EDP Sciences. - 2555-0403 .- 2267-1242. ; 246
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Over the last decades, strong focus has been placed on the energy efficiency of buildings; not least school buildings. Energy performance (EP) of buildings is nowadays in principle described by one single indicator based on purchased energy in kWh/year.m2. Another important building performance aspect is the indoor environmental quality. This study's overarching goal is to identify school buildings with a good balance between energy performance and indoor environment. Thus, this paper investigates possible correlations between information given in energy performance certificates (EPCs/e.g. energy use, year of construction, type of ventilation) and measured indoor environmental parameters. The work comprises investigation of approximately 20 school buildings with different ventilation systems in Gothenburg. In-situ investigations of the buildings' properties and ventilation systems were conducted. Indoor environmental parameters were recorded during one week in each classroom. In this paper, indoor temperature, absolute humidity added indoors and CO2 concentration data are compared with the corresponding school's energy performance data and ventilation type. Results suggest that mechanically ventilated buildings have clearer relationships between energy performance, building indicators and measured indoor environment. For buildings such as naturally ventilated, the relationships are usually weak, and the values spread over much wider ranges.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Byggproduktion (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Construction Management (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Annan naturresursteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Other Environmental Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy