SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:6d7d54b1-a295-46c1-afed-1dc2fc71b90b"
 

Sökning: id:"swepub:oai:research.chalmers.se:6d7d54b1-a295-46c1-afed-1dc2fc71b90b" > Influence of firing...

Influence of firing conditions and production methods on fracture strength of titanium-based metal ceramic crowns

Haag, P. (författare)
Malmö universitet,Odontologiska fakulteten (OD)
Khan, F. (författare)
Andersson, Martin, 1974 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Vult von Steyern, Per (författare)
Malmö universitet,Odontologiska fakulteten (OD)
visa färre...
 (creator_code:org_t)
2017-07-20
2018
Engelska.
Ingår i: Journal of Adhesion Science and Technology. - : Informa UK Limited. - 0169-4243 .- 1568-5616. ; 32:3, s. 225-238
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives: This study evaluated the effect of argon atmosphere compared with vacuum during porcelain firing on the fracture strength of crowns made of porcelain and electron beam melted (EBM) Ti-6Al-4 V, cast commercially pure titanium or milled commercially pure titanium. Methods: Sixty crown copings of c. p. titanium, Ti-6Al-4 V alloy and porcelain were fabricated using three production techniques. The copings were fired either under vacuum or in an argon gas atmosphere. Specimens were subdivided into groups of cast c. p. titanium, milled c. p. titanium and EBM Ti-6Al-4 V which were further subdivided according to firing modes employing either vacuum or argon gas. The 60 specimens were subjected to cyclic preloading and thermocycling, and were then individually loaded until interface fractured. Differences between the group mean values were calculated using the one-way ANOVA and Tukey's range test. Two fractured samples from each group were cut with a diamond blade and examined using SEM and EDS for visualization and chemical composition analysis of the fractured interface. Results: The highest mean fracture strength values, though not significant, were recorded for the groups fired in argon atmosphere, and the lowest mean fracture strength values were recorded for the groups fired in vacuum, with one exception. Comparing the two main groups of firing atmosphere, no significant difference could be documented. SEM and EDS analysis indicated clear differences in composition and structure between the groups included in the study. Conclusions: Firing in argon atmosphere does not significantly improve the fracture strength of porcelain bonded to titanium.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Sjukgymnastik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Physiotherapy (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Materialteknik -- Annan materialteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering -- Other Materials Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk material- och protesteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Materials (hsv//eng)

Nyckelord

argon
bond strength
dental ceramics
Titanium
dental porcelain

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy