SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:6fc0251f-3cba-4212-8835-6ee1f7f198d1"
 

Sökning: id:"swepub:oai:research.chalmers.se:6fc0251f-3cba-4212-8835-6ee1f7f198d1" > Analysis of the spi...

Analysis of the spinal 3D motion of postmortem human surrogates in nearside oblique impacts

Piqueras Lorente, Ana, 1989 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Pipkorn, Bengt, 1963 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Iraeus, Johan, 1973 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Juste-Lorente, Oscar (författare)
Universidad de Zaragoza,University of Zaragoza
Maza, Mario (författare)
Universidad de Zaragoza,University of Zaragoza
López-Valdés, Francisco (författare)
Universidad Pontificia Comillas
visa färre...
 (creator_code:org_t)
2022-12-13
2023
Engelska.
Ingår i: Traffic Injury Prevention. - : Informa UK Limited. - 1538-957X .- 1538-9588. ; 24:1, s. 69-74
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective : The objective of this study is to analyze the 6 degrees of freedom (DOF) motion of the spine using the finite helical axis (FHA) in three postmortem human surrogates (PMHS) sled tests. Methods : The sled test configurations corresponded to a 30° nearside oblique impact at 35 km/h. Two different restraint system versions (RSv) were used. RSv1 was used for PMHS A and B while RSv2 was used for PMHS C. The 6 DOF motion of the head and three selected vertebrae have been analyzed using the FHA which describes the 3 D motion of a rigid body between two instants of time as a rotation about and a translation along a unit vector. A minimal amount of rotation is necessary to the FHA calculation, thus the FHA components have been calculated based on a pre-defined interval of 8° of rotation. Results : The analysis of the FHA components demonstrated right lateral bending until around 100 ms, when the rebound phase was reached and the head and the lower spine undergoes left lateral bending. The three PMHS exhibited, in general, flexion movement of the whole body and torsion to the right side of the occupant. This general motion can be associated to the effect of the seatbelt acting as a fulcrum of the rotational movement of the bony landmarks. The interaction of the PMHS with the retention system can be noted by analyzing the time in which the head and the upper spine initiated the rotation and the sudden changes of rotational direction of the three PMHS’s head. Conclusions : The rotational analyses have shown to be more sensitive to experimental events than the trajectory analyses for the studied physical tests. Additionally, the results presented in the present study contributes to the analysis of the body kinematics during an oblique impact and adds new experimental data for Human Body Models (HBM) and Anthropometric Test Devices (ATD) benchmarking.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Farkostteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Vehicle Engineering (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Folkhälsovetenskap, global hälsa, socialmedicin och epidemiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Public Health, Global Health, Social Medicine and Epidemiology (hsv//eng)

Nyckelord

Finite helical axis, kinematics, nearside oblique impact, post mortem human surrogates, spine

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy