SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:7b70f9d3-3d09-4c60-9df9-5906f07f1d4b"
 

Sökning: id:"swepub:oai:research.chalmers.se:7b70f9d3-3d09-4c60-9df9-5906f07f1d4b" > Denoising of Scinti...

Denoising of Scintillation Camera Images Using a Deep Convolutional Neural Network: A Monte Carlo Simulation Approach

Minarik, David (författare)
Skånes universitetssjukhus (SUS),Skåne University Hospital
Enqvist, Olof, 1981 (författare)
Chalmers University of Technology
Trägårdh, Elin (författare)
Lund University,Lunds universitet,Nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,WCMM- Wallenberg center för molekylär medicinsk forskning,Medicinska fakulteten,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Nuclear medicine, Malmö,Lund University Research Groups,WCMM-Wallenberg Centre for Molecular Medicine,Faculty of Medicine,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
 (creator_code:org_t)
2019-07-19
2020
Engelska.
Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 2159-662X. ; 61:2, s. 298-303
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Scintillation camera images contain a large amount of Poisson noise. We have investigated whether noise can be removed in whole-body bone scans using convolutional neural networks (CNNs) trained with sets of noisy and noiseless images obtained by Monte Carlo simulation. Methods: Three CNNs were generated using 3 different sets of training images: simulated bone scan images, images of a cylindric phantom with hot and cold spots, and a mix of the first two. Each training set consisted of 40,000 noiseless and noisy image pairs. The CNNs were evaluated with simulated images of a cylindric phantom and simulated bone scan images. The mean squared error between filtered and true images was used as difference metric, and the coefficient of variation was used to estimate noise reduction. The CNNs were compared with gaussian and median filters. A clinical evaluation was performed in which the ability to detect metastases for CNN- and gaussian-filtered bone scans with half the number of counts was compared with standard bone scans. Results: The best CNN reduced the coefficient of variation by, on average, 92%, and the best standard filter reduced the coefficient of variation by 88%. The best CNN gave a mean squared error that was on average 68% and 20% better than the best standard filters, for the cylindric and bone scan images, respectively. The best CNNs for the cylindric phantom and bone scans were the dedicated CNNs. No significant differences in the ability to detect metastases were found between standard, CNN-, and gaussian-filtered bone scans. Conclusion: Noise can be removed efficiently regardless of noise level with little or no resolution loss. The CNN filter enables reducing the scanning time by half and still obtaining good accuracy for bone metastasis assessment.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
NATURVETENSKAP  -- Data- och informationsvetenskap -- Datorseende och robotik (hsv//swe)
NATURAL SCIENCES  -- Computer and Information Sciences -- Computer Vision and Robotics (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

artificial intelligence
nuclear medicine
machine learning
image enhancement
Monte Carlo
artificial intelligence
image enhancement
machine learning
Monte Carlo
nuclear medicine

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy