Analysis of the mechanical impedance of bone-anchored hearing aids
-
- Tjellström, A. (författare)
- Sahlgrenska universitetssjukhuset,Sahlgrenska University Hospital
-
- Håkansson, Bo, 1953 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Lindström, J. (författare)
- Sahlgrenska universitetssjukhuset,Sahlgrenska University Hospital
-
visa fler...
-
Brånemark, P. I. (författare)
-
- Hallén, O. (författare)
- Sahlgrenska universitetssjukhuset,Sahlgrenska University Hospital
-
- Rosenhall, U. (författare)
- Sahlgrenska universitetssjukhuset,Sahlgrenska University Hospital
-
- Leijon, Arne (författare)
- Sahlgrenska universitetssjukhuset,Sahlgrenska University Hospital
-
visa färre...
-
(creator_code:org_t)
- 2018-03-13
- 2018
- Engelska.
-
Ingår i: Acta Oto-Laryngologica. - : Informa UK Limited. - 1651-2251 .- 0001-6489. ; 138:3, s. 288-296
- Relaterad länk:
-
https://research.cha... (primary) (free)
-
visa fler...
-
https://www.tandfonl...
-
https://doi.org/10.1...
-
https://research.cha...
-
visa färre...
Abstract
Ämnesord
Stäng
- Some patients who need hearing aids are unable to use an apparatus which transmits the sound via the external ear canal and have to use a bone conduction hearing aid. The bone vibration transducer of this aid is applied to the skin over the mastoid process and the sound is transmitted via the soft tissue and bone to the cochlea. The pressure needed to apply the transducer often gives the patient discomfort and the damping effect of the soft tissue gives poor quality of the sound transmitted. Advances in the ability to permanently implant foreign material in the body and perform permanent skin penetration has made it possible to develop a bone-anchored hearing aid. Fourteen patients have been equipped with such hearing aids. To be able to give these patients the best hearing aid, a new transducer has to be constructed to match the new situation. The impedance of the bone-anchored titaniumscrew/skull has been studied and the resistance and reactance of the mechanical impedance have been measured. The influence of a damping soft tissue layer over the bone has been analyzed. The difference between the impedance of the skull and the impedance of the soft tissue + skull was in the order of 10 to 25 dB depending on the frequency.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Oto-rhino-laryngologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Otorhinolaryngology (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Industriell bioteknik -- Medicinsk bioteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Industrial Biotechnology -- Medical Biotechnology (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk material- och protesteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Materials (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas