SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:83c74489-60f2-4d3b-a972-49188cc29cd4"
 

Sökning: id:"swepub:oai:research.chalmers.se:83c74489-60f2-4d3b-a972-49188cc29cd4" > Field test of a flo...

Field test of a floating thermal pile in sensitive clay

Bergström, Anders (författare)
Nordic Construction Company AB - NCC,NCC AB
Javed, Saqib, 1978 (författare)
Lund University,Lunds universitet,Avdelningen för Installations- och klimatiseringslära,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Building Services,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
Dijkstra, Jelke, 1980 (författare)
Chalmers University of Technology
 (creator_code:org_t)
2021
2021
Engelska.
Ingår i: Geotechnique. - 0016-8505 .- 1751-7656. ; 71:4, s. 334-345
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The response of floating pile foundations in deep deposits of soft clay is governed by the settlements within the clay deposit surrounding the piles. A long-duration thermal response test (TRT) has been performed to assess the impact of heating and cooling on the geotechnical performance of a vertically loaded slender tubular steel pile in a deep deposit of sensitive clay. The results from the instrumented test site indicate that negligible excess pore water pressures, up to 3 kPa during heating and down to -1·1 kPa during cooling, were generated in the soil adjacent to the pile for a 50 W/m heat flux. The heating rate was sufficiently low to facilitate the drainage of pore water. The influence radius for the excess pore water pressures, however, extended beyond the soil volume affected by temperature change. The absence of thermally triggered creep settlements could be explained by the overlap between the remoulded zone resulting from pile installation, the extent of the heating, and the low creep susceptibility of remoulded sensitive clay for moderate temperature changes. Furthermore, no difference in the ultimate bearing capacity was found between the thermal pile and the reference pile, which was only loaded with a serviceability load during the test series. The current test data, therefore, indicate that driven floating piles in a deep deposit of soft clay also function as heat exchanger piles with minimal detrimental effects, for similar operational conditions as used in the TRT. It should be noted, however, that other pile types that do not extensively remould the clay adjacent to the pile shaft may show more significant influence of the thermal changes.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Geoteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Geotechnical Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Materialteknik -- Bearbetnings-, yt- och fogningsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering -- Manufacturing, Surface and Joining Technology (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Nyckelord

Full-scale tests
Consolidation
Clays
Temperature effects
Piles & piling
Creep
Settlement

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy