SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:9e7c6a4b-c8d6-4f0e-9749-57433744f465"
 

Sökning: id:"swepub:oai:research.chalmers.se:9e7c6a4b-c8d6-4f0e-9749-57433744f465" > Time intervals matr...

Time intervals matrix analysis of 235U and 239Pu content in a spent fuel assembly using Lead Slowing down Spectrometer

Chernikova, Dina, 1982 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Romodanov, V.L. (författare)
Sakharov, V.K. (författare)
 (creator_code:org_t)
2011
2011
Engelska.
Ingår i: Proceedings: Special Session on Determination of Pu Mass in Spent Fuel with NDA of the 52nd Annual Meeting of the Institute of Nuclear Materials Management.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • A key motivation for developing the technology capable of quantifying plutonium (Pu) in spent fuel assemblies with nondestructive assay (NDA) techniques is knowledge of the physical parameters of irradiated nuclear fuel which is important both for nuclear safeguards and nuclear fuel management. One of the most attractive NDA approaches applied for the determination of the total amount of plutonium using a pulsed neutron source is the method of slowing-down time spectrometry in lead where the energy spectrum of neutrons can be represented as being monoenergetic with minor deviation from the peak value in each time moment after a fast neutron pulse. This fact was successfully used in developing several methods of Pu mass determination and confirmed the potential of the Lead Slowing Down Spectrometer (LSDS) to get detailed information about spent fuel [1-2].A method which we presented earlier is based on a matrix of time intervals where large differences in the number of fissions of 235U and 239Pu are observed [3]. This technique allows increasing precision in the Pu evaluation by decreasing the self-shielding effect significantly. As opposed to homogeneous-volume approximations used in our previous research in this work we describe the detailed Monte Carlo models of real fuel assemblies, as well as the effects of the influence of the scintillation detector to the system in question. Although the proposed method for spent fuel assemblies characterization has only been studied using Monte Carlo simulations, it was possible to demonstrate the 239Pu determination using a DT pulsed neutron source, Lead Slowing Down Spectrometer and fast timing scintillatior which is sensitive to both photons and neutrons, and n-γ pulse shape discrimination allows to get additional information about the system.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Annan teknik -- Övrig annan teknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Other Engineering and Technologies -- Other Engineering and Technologies not elsewhere specified (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
vet (ämneskategori)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Chernikova, Dina ...
Romodanov, V.L.
Sakharov, V.K.
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Annan teknik
och Övrig annan tekn ...
Artiklar i publikationen
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy