Dispersal chambers used for evaluation of cleanroom and surgical clothing systems - examples of performed tests and results

Romano, Francesco (author)
Ljungqvist, Bengt, 1946 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Reinmüller, Berit, 1939 (author)
Chalmers tekniska högskola,Chalmers University of Technology
show more...
Gusten, Jan, 1952 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Joppolo, Cesare M. (author)
show less...
 (creator_code:org_t)
2016
2016
English.
In: International Symposium on Contamination Control, ICCCS, Sao Paulo, Brazil sept 2016.
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • Chalmers University of Technology in Sweden and Politecnico di Milano in Italy have developed and installed two experimental dispersal chambers (body-box) for the measurement of the rate of total and microbial airborne particle dispersion from persons (wearing technical clothing system) and from equipment in cleanrooms and in Operating Theaters (OT). This paper describes the two dispersal chambers and the adopted test procedures for person particle dispersion tests. The release rate of total airborne particles (in defined particle size ranges) emitted from a person and his gowning system while performing standard movements and the release rate of aerobic Colony Forming Unit (CFU) of the same person and gowning system, can be considered as the personnel source strenght, a fundamental parameter both in design and in operation of a clean space. Moreover, the personnel source strength data could be used in order to compare technical clothing systems in terms of their particle shedding, and even more interestingly in terms of their ability to filter and to limit the personnel airborne particler release. The study presents data obtained in experimental compaigns made in the two labs. The results of the experimental tests carried out on different technical clothing systems are discussed and compared, highlighting the effect on emission rates of the garment type and of the number of undergone cycles of Washing, Drying and Sterilization (WDS). The source strenght data presented in this paper can be used in the design phase of cleanrooms and of OT to size the total air flow required for contamination control and to forecast the concentrations of aerobic CFUs and total airborne particles.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering (hsv//eng)

Keyword

Source Strength
Surgical and Cleanroom Clothing Systems
Dispersal chamber
Body box
Contamination Control

Publication and Content Type

kon (subject category)
ref (subject category)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Romano, Francesc ...
Ljungqvist, Beng ...
Reinmüller, Beri ...
Gusten, Jan, 195 ...
Joppolo, Cesare ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Civil Engineerin ...
Articles in the publication
By the university
Chalmers University of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view