A Priori Assessment of Adipose Tissue Mechanical Testing by Global Sensitivity Analysis

Naseri, Hosein, 1987 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Johansson, Håkan, 1979 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
 (creator_code:org_t)
2018-03-05
2018
Engelska.
Ingår i: Journal of Biomechanical Engineering. - : ASME International. - 0148-0731 .- 1528-8951. ; 140:5
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In modelling the mechanical behavior of soft tissues, the proper choice of an experiment for identifying material parameters is not an easy task. In this study, a finite element computational framework is used to virtually simulate and assess commonly used experimental setups; rotational rheometer tests, confined- and unconfined- compression tests, and indentation tests. Variance-based global sensitivity analysis is employed to identify which parameters in different experimental setups govern model prediction, and are thus more likely to be determined through parameter identification processes. Therefore, a priori assessment of experimental setups provides a base for systematic and reliable parameter identification. It is found that in indentation tests and unconfined-compression tests, incompressibility of soft tissues (adipose tissue in this study) plays an important role at high strain rates. That means bulk stiffness constitutes the main part of the mechanism of tissue response, thus these experimental setups may not be appropriate for identifying shear stiffness. Also, identified material parameters through loading-unloading shear tests at a certain rate might not be reliable for other rates, since adipose tissue shows highly strain rate dependent behavior. Frequency sweep tests at a wide-enough frequency range seem to be the best setup to capture the strain rate behavior. Moreover, analyzing the sensitivity of model parameters in the different experimental setups provides further insight about the model itself.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)
NATURVETENSKAP  -- Biologi -- Biofysik (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Biophysics (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Materialteknik -- Annan materialteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering -- Other Materials Engineering (hsv//eng)

Nyckelord

global sensitivity analysis
experimental setup assessment
soft tissue
parameter identification

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Naseri, Hosein, ...
Johansson, Håkan ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Annan medicintek ...
NATURVETENSKAP
NATURVETENSKAP
och Biologi
och Biofysik
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Materialteknik
och Annan materialte ...
Artiklar i publikationen
Journal of Biome ...
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy