Internal thermal environment and futureproofing of a newly built, naturally ventilated UK school

Stephen, Jake (författare)
University of Southampton
Bourikas, Leonidas (författare)
Lancaster University
Teli, Despoina, 1980 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Bahaj, Abubakr (författare)
University of Southampton
Congreve, Richard (författare)
visa färre...
 (creator_code:org_t)
IOP Publishing, 2020
2020
Engelska.
Ingår i: IOP Conference Series: Earth and Environmental Science. - : IOP Publishing. - 1755-1307 .- 1755-1315. ; 588:3
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Research indicates that school children have lower comfort levels than adults and this exacerbates the challenge of tackling the risks of summer overheating in schools without resorting to air conditioning. UN SDG 13 calls for climate action to strengthen the resilience of our cities and reduce the impact of climate change. In this work, a modern, naturally ventilated school in Southampton, UK was used to evaluate single, "hard", passive retrofit measures and "soft", building management solutions that could increase the wellbeing of students and reduce current and future demand for cooling. The school was selected as it represents the current standardised design guidance for schools released in 2012 by the Department of Education (DfE). The research presents air temperature observations collected during the summer of 2015. Dynamic thermal modelling was undertaken to evaluate passive retrofit and "soft" solutions to reduce the overheating risk. The model was validated with temperature data collected from the school classrooms. The results indicate that (a) such school buildings have high likelihood of overheating, based on children's comfort temperatures and (b) passive retrofits focused on shading and ventilation could help to reduce the classroom temperature when required. It is recommended that "soft" adaptive solutions will prove effective to reduce future air conditioning demand, but this will require a radical change in established practices. Achieving the UN Sustainable Development Goals by 2030 will require to rethink and redesign urban living and city infrastructures.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Arkitekturteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Architectural Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Annan samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Other Civil Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Nyckelord

Children's thermal comfort
Summer overheating
School buildings
Cooling demand
Passive retrofits

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy