Sökning: id:"swepub:oai:research.chalmers.se:cbbf147a-821b-4754-91d1-f6214d2fa4ac" >
Semi-automatic bord...
Semi-automatic border detection software for the quantification of arterial lumen, intima-media and adventitia layer thickness with very-high resolution ultrasound
-
- Sundholm, Johnny (författare)
- Helsingin Yliopisto,University of Helsinki
-
- Gustavsson, Tomas, 1954 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Sarkola, Taisto (författare)
- Helsingin Yliopisto,University of Helsinki
-
(creator_code:org_t)
- Elsevier BV, 2014
- 2014
- Engelska.
-
Ingår i: Atherosclerosis. - : Elsevier BV. - 1879-1484 .- 0021-9150. ; 234:2, s. 283-287
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://helda.helsin...
-
https://research.cha...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background: The aim was to evaluate the accuracy, precision and feasibility of semi-automatic border detection software (AMS) in comparison to manual electronic calipers (EC) in the analysis of arterial images obtained with transcutaneous very-high resolution vascular ultrasound (VHRU, 25-55 MHz). Methods: 100 images from central elastic and peripheral muscular arteries were obtained on two separate imaging occasions from 10 healthy subjects, and independently measured with AMS and EC. Results: No bias between AMS and EC was found. The intraobserver coefficients of variation (CV) for carotid lumen dimension (mean dimension 5.60 mm) was lower with AMS compared with EC (0.4 vs. 1.9%, p = 0.033; N = 20). No consistently significant differences in intra, inter or test-retest CVs were observed overall for muscular artery dimensions between AMS and EC. The intra CV for adventitial thickness (AT, mean 0.111 mm; 15.6 vs 24.8%, p = 0.011; N 41) and inter CV for intima-media thickness (IMT, mean 0.219 mm; 14.3 vs. 21.2%, p = 0.001; N = 58) obtained with AMS in higher quality thin muscular artery images was lower compared with EC. The mean reading time was significantly lower with AMS compared with EC (71.5 s vs. 156.6 s, p
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Nyckelord
- disease
- clinical measurement
- feasibility
- wall
- risk
- computerized analyzing system
- carotid ultrasound
- variability
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas