Monitoring corrosion-induced concrete cracking adjacent to the steel-concrete interface

Alhede, Andreas, 1996 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Dijkstra, Jelke, 1980 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Lundgren, Karin, 1968 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
 (creator_code:org_t)
2023
2023
Engelska.
Ingår i: Materials and Structures/Materiaux et Constructions. - 1359-5997. ; 56:9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Substantial research effort has been devoted on linking corrosion-induced cracking of concrete with the internal corrosion damage level. Still, numerical models of the corrosion and cracking process require internal parameters, that cannot be directly evaluated from experimental data. Therefore, this study provides a novel experimental method for monitoring the effects of steel corrosion adjacent to the steel-concrete interface. This non-destructive method is suited for small-scale laboratory-made specimen, and was designed to provide missing information required for subsequent calibration of numerical models. Hollow steel bars were cast into concrete and subjected to accelerated corrosion using the impressed current technique. The deformations of the hollow steel bars were measured using distributed strain sensing in an optical fibre, attached to the inner surface of the hollow steel bars. After the corrosion period, X-ray Computed Tomography scans were performed to evaluate concrete cracking and corrosion level. The results reveal a non-uniform distribution of strain around the perimeter of the steel, indicating a non-uniform radial stress distribution. The non-uniformity correlated very well with the position of the corrosion-induced cracks; with extension hoop strains in the steel at the location of these cracks and contraction hoop strains in between. Further, the corrosion level varied around the perimeter, with higher values near cracks. The combination of non-destructive monitoring techniques used in this study on small-scale laboratory-made specimens show great potential to reveal new insights on how the corrosion pattern, corrosion-induced cracking of the concrete cover and stress (indirectly measured through the strain in the steel) interact throughout the corrosion process.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Teknisk mekanik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Applied Mechanics (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Infrastrukturteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Infrastructure Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Materialteknik -- Annan materialteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering -- Other Materials Engineering (hsv//eng)

Nyckelord

Distributed optical strain sensing
Corrosion
X-ray computed tomography
Steel-concrete interface
Reinforced concrete
Concrete cracking

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy