Applying exergy and total site analysis for targeting refrigeration shaft power in industrial clusters

Hackl, Roman, 1981 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Harvey, Simon, 1965 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
 (creator_code:org_t)
Elsevier BV, 2013
2013
Engelska.
Ingår i: Energy. - : Elsevier BV. - 0360-5442 .- 1873-6785. ; 55, s. 5-14
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Process cooling below ambient temperature is an energy demanding part of many chemical production processes. Compression refrigeration systems operating at very low temperatures consume a lot of high quality utility such as electricity or high pressure steam to drive the compressor units. In industrial process clusters with several processes operating at low temperatures, it is important to investigate opportunities for exchange of low-temperature energy between processes. This paper demonstrates how total site analysis and exergy analysis can be applied to target for shaft power and related hot utility savings for processes and utility systems operating below ambient temperature. Shaft power targeting by optimizing refrigerant use is conducted. In addition the methodology is extended for shaft power targeting in connection with site-wide heat recovery from cold process streams to generate sub-ambient utility. The methodology is illustrated through application to a case study of a chemical cluster. One chemical plant within the cluster operates two compression refrigeration systems at its steam cracker plant. The results of the case study indicate potential savings of 1.5 MW of shaft power by optimizing the use of refrigerant from the compression refrigeration system and additional 2.5 MW of shaft power by recovering refrigeration from two other sites located outside the cracker plant. In total this corresponds to 15% of the total shaft power consumption of the refrigeration systems. Economic evaluation of the proposed measures indicates a pay-back period of approximately 4 years.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Kemiteknik -- Annan kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering -- Other Chemical Engineering (hsv//eng)

Nyckelord

Exergy analysis
Industrial refrigeration systems
Process integration
Total site analysis
Pinch analysis

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Energy (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hackl, Roman, 19 ...
Harvey, Simon, 1 ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Kemiteknik
och Annan kemiteknik
Artiklar i publikationen
Energy
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy