Fluorescent vesicles for signal amplification in reverse phase protein microarray assays

Bally, Marta, 1981 (författare)
Syed, S. (författare)
Binkert, A. (författare)
visa fler...
Kauffmann, E. (författare)
Ehrat, M. (författare)
Vörös, J. (författare)
visa färre...
2011
2011
Engelska.
Ingår i: Analytical Biochemistry. - 0003-2697 .- 1096-0309. ; 416:2, s. 145-151
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Developments in microarray technology promise to lead to great advancements in the biomedical and biological field. However, implementation of these analytical tools often relies on signal amplification strategies that are essential to reach the sensitivity levels required for a variety of biological applications. This is true especially for reverse phase arrays where a complex biological sample is directly immobilized on the chip. We present a simple and generic method for signal amplification based on the use of antibody-tagged fluorescent vesicles as labels for signal generation. To assess the gain in assay sensitivity, we performed a model assay for the detection of rabbit immunoglobulin G (IgG) and compared the limit of detection (LOD) of the vesicle assay with the LOD of a conventional assay performed with fluorescent reporter molecules. We evaluated the improvements for two fluorescence-based transduction setups: a high-sensitivity microarray reader (ZeptoREADER) and a conventional confocal scanner. In all cases, our strategy led to an increase in sensitivity. However, gain in sensitivity widely depended on the type of illumination; whereas an approximately 2-fold increase in sensitivity was observed for readout based on evanescent field illumination, the contribution was as high as more than 200-fold for confocal scanning. (C) 2011 Elsevier Inc. All rights reserved.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

phospholipid vesicle
reverse assay
immunoassays
platform
fluorescence
proteomics
technology
protein microarray
microfluidic biosensor
labels
nanoparticles
liposomes
wave-guides
probes
high-sensitivity immunoassay

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy