Sökning: id:"swepub:oai:research.chalmers.se:d5129053-2aa9-4c28-b7fb-f860c4acd392" >
A high-throughput m...
A high-throughput method for liquid chromatography-tandem mass spectrometry determination of plasma alkylresorcinols, biomarkers of whole grain wheat and rye intake.
-
- Ross, Alastair, 1976 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Svelander, Cecilia, 1980 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Savolainen, Otto, 1982 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
visa fler...
-
- Vendelbo Lind, Mads, 1988 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Kirwan, J.P. (författare)
- Cleveland Clinic Foundation
-
- Breton, I. (författare)
- Nestle S.A.
-
- Godin, J. P. (författare)
- Nestle S.A.
-
- Sandberg, Ann-Sofie, 1951 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2016
- 2016
- Engelska.
-
Ingår i: Analytical Biochemistry. - : Elsevier BV. - 0003-2697 .- 1096-0309. ; 499, s. 1-7
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://research.cha...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Plasma alkylresorcinols are increasingly analyzed in cohort studies to improve estimates of whole grain intake and their relationship with disease incidence. Current methods require large volumes of solvent (>10 ml/sample) and have relatively low daily sample throughput. We tested five different supported extraction methods for extracting alkylresorcinols from plasma and improved a normal-phase liquid chromatography coupled to a tandem mass spectrometer method to reduce sample analysis time. The method was validated and compared with gas chromatography-mass spectrometry analysis. Sample preparation with HybridSPE supported extraction was most effective for alkylresorcinol extraction, with recoveries of 77-82% from 100 μl of plasma. The use of 96-well plates allowed extraction of 160 samples per day. Using a 5-cm NH2 column and heptane reduced run times to 3 min. The new method had a limit of detection and limit of quantification equivalent to 1.1-1.8 nmol/L and 3.5-6.1 nmol/L plasma, respectively, for the different alkylresorcinol homologues. Accuracy was 93-105%, and intra- and inter-batch precision values were 4-18% across different plasma concentrations. This method makes it possible to quantify plasma alkylresorcinols in 100 μl of plasma at a rate of at least 160 samples per day without the need for large volumes of organic solvents.
Ämnesord
- NATURVETENSKAP -- Kemi -- Analytisk kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Hälsovetenskap -- Näringslära (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Health Sciences -- Nutrition and Dietetics (hsv//eng)
Nyckelord
- whole grain
- Alkylresorcinols
- intake
- Plasma biomarkers
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas