SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:d8b1fa3c-1a59-4940-afe0-87ae3109d2a0"
 

Sökning: id:"swepub:oai:research.chalmers.se:d8b1fa3c-1a59-4940-afe0-87ae3109d2a0" > On-ScalpMEG

On-ScalpMEG

Schneiderman, Justin, 1979 (författare)
Göteborgs universitet,University of Gothenburg
Ruffieux, Silvia, 1990 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Pfeiffer, Christoph, 1989 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Riaz, B. (författare)
Göteborgs universitet,University of Gothenburg
visa färre...
 (creator_code:org_t)
2019-10-18
2019
Engelska.
Ingår i: Magnetoencephalography: From Signals to Dynamic Cortical Networks: Second Edition. - Cham : Springer International Publishing. ; , s. 1313-1335
  • Bokkapitel (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • The development of new magnetic sensor technologies with relaxed thermal insulation requirements as compared to conventional magnetoencephalography (MEG) sensors has led to the birth of the field of on-scalp MEG, where sensor systems are flexibly placed directly on the scalp surface. Such improved proximity between the sensors and the brain has been theoretically demonstrated to boost signal levels and neuroimaging spatial resolution. Since the first on-scalp MEG measurements in 2012, a number of studies have experimentally verified these advantages with the two leading sensor technologies, namely, high criticaltemperature SQUIDs (high-Tc SQUIDs) and optically pumped magnetometers (OPMs). Current challenges being addressed that are specific to on-scalp MEG include relatively high sensor noise levels (specifically for high-Tc SQUIDs), limited bandwidth (specifically for OPMs), co-registration of a flexible sensor array, increased sensor crosstalk due to the denser spatial sampling required for improved spatial resolution, and engineering of a full-head system. The prospect for discovery of a neuroimaging challenge that on-scalp MEG uniquely solves is likely to push development further and possibly initiate utilization to a similar-or larger-scale as conventional MEG has reached today.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Inbäddad systemteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Embedded Systems (hsv//eng)

Nyckelord

Shielding
Multichannel
Spatial sampling
MEG system
Crosstalk
Superconducting quantum interference device (SQUID)
Spatial resolution
On-scalp MEG
Standoff
High-Tc SQUID
Magnetoencephalography (MEG)
Magnetometer
Optically pumped magnetometer (OPM)
Co-registration
Flexible sensor array

Publikations- och innehållstyp

kap (ämneskategori)
vet (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Schneiderman, Ju ...
Ruffieux, Silvia ...
Pfeiffer, Christ ...
Riaz, B.
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Annan medicintek ...
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Elektroteknik oc ...
och Inbäddad systemt ...
Artiklar i publikationen
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy