Improving and upgrading an existing activated sludge with a compact MBBR - disc filters parallel line for municipal wastewater treatment in touristic alpine areas.

Desa, L. (författare)
Veolia Water Technologies
Kängsepp, Pille (författare)
Kristianstad University,Veolia Water Technologies
Quadri, L. (författare)
Veolia Water Technologies
visa fler...
Bellotti, G. (författare)
Veolia Water Technologies
Sorensen, K. (författare)
Veolia Water Technologies
Pellicer-Nacher, C. (författare)
Veolia Water Technologies
visa färre...
 (creator_code:org_t)
2020-05-12
2020
Engelska 12
Ingår i: Water Practice and Technology. - : IWA Publishing. - 1751-231X. ; 15:2, s. 515-527
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Many wastewater treatment plants (WWTP) in touristic areas struggle to achieve the effluent requirements due to seasonal variations in population. In alpine areas, the climate also determines a low wastewater temperature, which implies long sludge retention time (SRT) needed for the growth of nitrifying biomass in conventional activated sludge (CAS). Moreover, combined sewers generate high flow and dilution. The present study shows how the treatment efficiency of an existing CAS plant with tertiary treatment can be upgraded by adding a compact line in parallel, consisting of a Moving Bed Biofilm Reactor (MBBR)-coagulation-flocculation-disc filtration. This allows the treatment of influent variations in the MBBR and a constant flow supply to the activated sludge. The performance of the new 2-step process was comparable to that of the improved existing one. Regardless significant variations in flow (10,000-25,000 m(3)/d) and total suspended solids (TSS) (50-300 mg/L after primary treatment) the effluent qualityfulfilled the discharge requirements. Based on yearly average effluent data, TSS were 11 mg/L, chemical oxygen demand (COD) 27 mg/L and total phosphorus (TP) 0.8 mg/L. After the upgrade, ammonium nitrogen (NH4-N) dropped from 4.9 mg/L to 1.3 mg/L and the chemical consumption for phosphorus removal was reduced.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy