SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:slubar.slu.se:106817"
 

Sökning: id:"swepub:oai:slubar.slu.se:106817" > Automatic detection...

Automatic detection of break-over phase onset in horses using hoof-mounted inertial measurement unit sensors

Hernlund, Elin (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för anatomi, fysiologi och biokemi,Department of Anatomy, Physiology and Biochemistry (AFB)
Rhodin, Marie (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för anatomi, fysiologi och biokemi,Department of Anatomy, Physiology and Biochemistry (AFB)
 (creator_code:org_t)
 
2020-05-29
2020
Engelska.
Ingår i: PLoS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 15
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A prolonged break-over phase might be an indication of a variety of musculoskeletal disorders and can be measured with optical motion capture (OMC) systems, inertial measurement units (IMUs) and force plates. The aim of this study was to present two algorithms for automatic detection of the break-over phase onset from the acceleration and angular velocity signals measured by hoof-mounted IMUs in walk and trot on a hard surface. The performance of these algorithms was evaluated by internal validation with an OMC system and a force plate separately. Seven Warmblood horses were equipped with two wireless IMUs which were attached to the lateral wall of the right front (RF) and hind (RH) hooves. Horses were walked and trotted over a force plate for internal validation while simultaneously the 3D position of three reflective markers, attached to lateral heel, lateral toe and lateral coronet of each hoof, were measured by six infrared cameras of an OMC system. The performance of the algorithms was evaluated by linear mixed model analysis. The acceleration algorithm was the most accurate with an accuracy between -9 and 23 ms and a precision around 24 ms (against OMC system), and an accuracy between -37 and 20 ms and a precision around 29 ms (against force plate), depending on gait and hoof. This algorithm seems promising for quantification of the break-over phase onset although the applicability for clinical purposes, such as lameness detection and evaluation of trimming and shoeing techniques, should be investigated more in-depth.

Ämnesord

LANTBRUKSVETENSKAPER  -- Veterinärmedicin -- Medicinsk biovetenskap (hsv//swe)
AGRICULTURAL SCIENCES  -- Veterinary Science -- Medical Bioscience (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • PLoS ONE (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hernlund, Elin
Rhodin, Marie
Om ämnet
LANTBRUKSVETENSKAPER
LANTBRUKSVETENSK ...
och Veterinärmedicin
och Medicinsk biovet ...
Artiklar i publikationen
PLoS ONE
Av lärosätet
Sveriges Lantbruksuniversitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy