Sökning: onr:"swepub:oai:DiVA.org:liu-21206"
> Styner M >
Standardized evalua...
Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms
-
- Schaap, M. (författare)
- Biomedical Imaging Group Rotterdam, The Netherlands
-
- Metz, C.T. (författare)
- Biomedical Imaging Group Rotterdam, The Netherlands,Universidad Politécnica de Madrid, Spain
-
- van Walsum, T. (författare)
- Biomedical Imaging Group Rotterdam, The Netherlands
-
visa fler...
-
- van der Giessen, A.G. (författare)
- Biomedical Imaging Group Rotterdam, The Netherlands
-
- Weustink, A.C. (författare)
- Erasmus MC, Rotterdam, The Netherlands
-
- Mollet, N.R. (författare)
- Erasmus MC, Rotterdam, The Netherlands
-
- Bauer, C. (författare)
- Graz University of Technology, Austria
-
- Bogunovic, H. (författare)
- Center for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), Barcelona, Spain
-
- Castro, C. (författare)
- Universidad Politécnica de Madrid, Spain,MeVis Research, Bremen, Germany
-
- Deng, X. (författare)
- Siemens Corporate Research, Princeton, NJ, USA
-
- Dikici, E. (författare)
- University of Florida College of Medicine, Jacksonville, FL, USA
-
- O'Donnell, T. (författare)
- Siemens Corporate Research, Princeton, NJ, USA
-
- Frenay, M. (författare)
- Leiden University Medical Center, The Netherlands
-
- Friman, O. (författare)
- MeVis Research, Bremen, Germany
-
- Hoyos, M.H. (författare)
- Universidad de los Andes, Bogota, Colombia
-
- Kitslaar, P.H. (författare)
- Leiden University Medical Center, The Netherlands
-
- Krissian, K. (författare)
- University of Las Palmas of Gran Canaria, Spain,Childrens Hospital Boston, MA, USA
-
- Kuhnel, C. (författare)
- MeVis Research, Bremen, Germany
-
- Luengo-Oroz, M.A. (författare)
- Universidad Politécnica de Madrid, Spain
-
- Orkisz, M. (författare)
- Université de Lyon, France
-
- Smedby, Örjan (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Röntgenkliniken i Linköping
-
- Styner, M. (författare)
- University of North Carolina, Chapel Hill, NC, USA
-
- Szymczak, A. (författare)
- Colorado School of Mines, Golden, CO, USA
-
- Tek, H. (författare)
- Siemens Corporate Research, Princeton, NJ, USA
-
- Wang, Chunliang (författare)
- Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Linköping Univ., Linköping, Sweden
-
- Warfield, S.K. (författare)
- Childrens Hospital Boston, MA, USA
-
- Zambal, S. (författare)
- VRVis Research Center for Virtual Reality and Visualization, Vienna, Austria
-
- Zhang, Y. (författare)
- The Methodist Hospital Research Institute, Houston, TX, USA
-
- Krestin, G.P. (författare)
- Erasmus MC, Rotterdam, The Netherlands
-
- Niessen, W.J. (författare)
- Erasmus MC, Rotterdam, The Netherlands
-
visa färre...
-
(creator_code:org_t)
- Elsevier, 2009
- 2009
- Engelska.
-
Ingår i: Medical Image Analysis. - : Elsevier. - 1361-8415 .- 1361-8423. ; 13:5, s. 701-714
- Relaterad länk:
-
https://cdr.lib.unc....
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Efficiently obtaining a reliable coronary artery centerline from computed tomography angiography data is relevant in clinical practice. Whereas numerous methods have been presented for this purpose, up to now no standardized evaluation methodology has been published to reliably evaluate and compare the performance of the existing or newly developed coronary artery centerline extraction algorithms. This paper describes a standardized evaluation methodology and reference database for the quantitative evaluation of coronary artery centerline extraction algorithms. The contribution of this work is fourfold: (1) a method is described to create a consensus centerline with multiple observers, (2) well-defined measures are presented for the evaluation of coronary artery centerline extraction algorithms, (3) a database containing 32 cardiac CTA datasets with corresponding reference standard is described and made available, and (4) 13 coronary artery centerline extraction algorithms, implemented by different research groups, are quantitatively evaluated and compared. The presented evaluation framework is made available to the medical imaging community for benchmarking existing or newly developed coronary centerline extraction algorithms.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Image Processing (hsv//eng)
Nyckelord
- Centerline extraction; Computed tomography; Coronaries; Standardized evaluation; Tracking
- MEDICINE
- MEDICIN
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Schaap, M.
-
Metz, C.T.
-
van Walsum, T.
-
van der Giessen, ...
-
Weustink, A.C.
-
Mollet, N.R.
-
visa fler...
-
Bauer, C.
-
Bogunovic, H.
-
Castro, C.
-
Deng, X.
-
Dikici, E.
-
O'Donnell, T.
-
Frenay, M.
-
Friman, O.
-
Hoyos, M.H.
-
Kitslaar, P.H.
-
Krissian, K.
-
Kuhnel, C.
-
Luengo-Oroz, M.A ...
-
Orkisz, M.
-
Smedby, Örjan
-
Styner, M.
-
Szymczak, A.
-
Tek, H.
-
Wang, Chunliang
-
Warfield, S.K.
-
Zambal, S.
-
Zhang, Y.
-
Krestin, G.P.
-
Niessen, W.J.
-
visa färre...
- Om ämnet
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Medicinteknik
-
och Medicinsk bildbe ...
- Artiklar i publikationen
-
Medical Image An ...
- Av lärosätet
-
Linköpings universitet
-
Kungliga Tekniska Högskolan