SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "swepub ;pers:(Larsson Anders);lar1:(kth);conttype:(refereed);pers:(Nyholm Sten E.);pers:(Möller Cecilia)"

Sökning: swepub > Larsson Anders > Kungliga Tekniska Högskolan > Refereegranskat > Nyholm Sten E. > Möller Cecilia

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Elfsberg, Mattias, et al. (författare)
  • Experimental Studies of Anode and Cathode Materials in a Repetitive Driven Axial Vircator
  • 2008
  • Ingår i: IEEE Transactions on Plasma Science. - 0093-3813. ; 36, s. 688-693
  • Tidskriftsartikel (refereegranskat)abstract
    •  Repetitive use of a high-power microwave (HPM) radiation source implies strong erosion on cathode and anode materials. Electrode material endurance has been studied in a series of experiments with an axial vircator powered by a compact Marx generator. The Marx generator operated in a 10 Hz repetitive mode with a burst of ten pulses. Velvet and graphite was used as electron-emitting materials, and they showed markedly different pulse characteristics. Three different anode materials were used; stainless steel mesh, stainless steel wires and molybdenum wires, which all had different influence on the pulse characteristics.
  •  
2.
  • Novac, Bucur M., et al. (författare)
  • A 10-GW pulsed power supply for HPM sources
  • 2006
  • Ingår i: IEEE TRANS PLASMA SCI. ; s. 1814-1821
  • Konferensbidrag (refereegranskat)abstract
    • A research activity involving the detailed consideration of novel high-voltage transformers for pulsed-power applications has recently begun at Loughborough University. Although the main goal is the demonstration of a compact and lightweight unit employing magnetic insulation under vacuum conditions, the initial stage of the work is directed toward the development of a conventional air-cored transformer as a main component in a compact power supply for high power microwave sources. In cooperation with the Swedish Defence Research Agency (FOI), the power supply has been tested with a microwave source of the vircator type. The power generator for the system uses a 70-kJ/25-kV capacitor bank and an exploding wire array to generate a 150-kV voltage pulse in the primary circuit of a transformer. A pressurized SF6 spark gap in the secondary circuit sharpens the high-voltage output so that pulses approaching 500 kV and with a rise time well below 100 ns are generated on a 20-Omega high-power resistors With the peak power in excess of 10 GW. Experimental results are presented from final testing of the system, where a reflex triode vircator replaces the 20-Omega resistor. Measurements of the microwave emission using free-field sensors are presented, and comments are made with the microwave emission from the same vircator when powered by a Marx generator at FOI.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (1)
konferensbidrag (1)
Typ av innehåll
Författare/redaktör
Hurtig, Tomas (2)
Elfsberg, Mattias (2)
Appelgren, Patrik, (1)
visa fler...
Novac, Bucur M. (1)
Moller, Cecilia (1)
Brown, John (1)
Istenic, Marko (1)
Luo, Jing (1)
Smith, Ivor R. (1)
Hubbard, Martin (1)
visa färre...
Lärosäte
Uppsala universitet (1)
Språk
Engelska (2)
Ämne (HSV)
Naturvetenskap (1)

År

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy