SwePub
Sök i LIBRIS databas

  Utökad sökning

swepub
 

Sökning: swepub > Engelska > Örebro universitet > Mälardalens universitet > Nyholm Dag > Automatic and objec...

Automatic and objective assessment of alternating tapping performance in Parkinson’s disease

Memedi, Mevludin (författare)
Örebro universitet,Högskolan Dalarna,Datateknik,Institutionen för naturvetenskap och teknik,School of Technology and Business Studies, Computer Engineering, Dalarna University, Falun, Sweden
Khan, Taha (författare)
Mälardalens högskola,Högskolan Dalarna,Datateknik,School of Technology and Business Studies, Computer Engineering, Dalarna University, Falun, Sweden; School of Innovation, Design and Technology, Mälardalen University, Västerås, Sweden,Innovation och produktrealisering
Grenholm, Peter (författare)
Uppsala universitet,Neurologi
visa fler...
Nyholm, Dag (författare)
Uppsala universitet,Neurologi
Westin, Jerker (författare)
Högskolan Dalarna,Datateknik,School of Technology and Business Studies, Computer Engineering, Dalarna University, Falun, Sweden
visa färre...
 (creator_code:org_t)
2013-12-09
2013
Engelska.
Ingår i: Sensors. - Basel : MDPI AG. - 1424-8220. ; 13:12, s. 16965-16984
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper presents the development and evaluation of a method for enabling quantitative and automatic scoring of alternating tapping performance of patients with Parkinson’s disease (PD). Ten healthy elderly subjects and 95 patients in different clinical stages of PD have utilized a touch-pad handheld computer to perform alternate tapping tests in their home environments. First, a neurologist used a web-based system to visually assess impairments in four tapping dimensions (‘speed’, ‘accuracy’, ‘fatigue’ and ‘arrhythmia’) and a global tapping severity (GTS). Second, tapping signals were processed with time series analysis and statistical methods to derive 24 quantitative parameters. Third, principal component analysis was used to reduce the dimensions of these parameters and to obtain scores for the four dimensions. Finally, a logistic regression classifier was trained using a 10-fold stratified cross-validation to map the reduced parameters to the corresponding visually assessed GTS scores. Results showed that the computed scores correlated well to visually assessed scores and were significantly different across Unified Parkinson’s Disease Rating Scale scores of upper limb motor performance. In addition, they had good internal consistency, had good ability to discriminate between healthy elderly and patients in different disease stages, had good sensitivity to treatment interventions and could reflect the natural disease progression over time. In conclusion, the automatic method can be useful to objectively assess the tapping performance of PD patients and can be included in telemedicine tools for remote monitoring of tapping.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Datorsystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Computer Systems (hsv//eng)
NATURVETENSKAP  -- Data- och informationsvetenskap -- Datavetenskap (hsv//swe)
NATURAL SCIENCES  -- Computer and Information Sciences -- Computer Sciences (hsv//eng)
NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

alternating tapping
touch-pad
handheld computer
telemedicine
Parkinson’s disease
remote monitoring
automatic assessment
objective assessment
visual assessment
PAULINA - Uppföljning av Parkinsonsymptom från hemmet
PAULINA - Uppföljning av Parkinsonsymptom från hemmet
Datavetenskap

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Sensors (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy