SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Maibach Howard I.) ;mspu:(article)"

Search: WFRF:(Maibach Howard I.) > Journal article

  • Result 1-10 of 14
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • 2019
  • Journal article (peer-reviewed)
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  • Morgardt-Ryberg, Kristina, et al. (author)
  • Patch testing with a textile dye mix - a multicentre study.
  • 2014
  • In: Contact Dermatitis. - : Wiley. - 0105-1873. ; 71:4, s. 215-223
  • Journal article (peer-reviewed)abstract
    • Disperse dyes are well-known contact sensitizers. However, they are not included in the majority of commercially available baseline patch test series.
  •  
8.
  • Nilsson, Gert, et al. (author)
  • Cutaneous bioengineering instrumentation standardization : the Tissue Viability Imager
  • 2009
  • In: Skin research and technology. - : Wiley. - 0909-752X .- 1600-0846. ; 15:1, s. 6-13
  • Journal article (peer-reviewed)abstract
    • Tissue Viability Imaging (TiVi) is a new bioengineering technology intended for remote two-dimensional mapping of skin red blood cell concentration (RBCconc). Before use in the laboratory, work-site and dermatology clinic, critical performance parameters of this emerging technology require careful evaluation. To assess short- and long-term stability, image uniformity, distance and image size dependence, ambient light and curvature influence in a production batch of Tissue Viability Imagers. Four Tissue Viability Imagers from the same production batch were evaluated at two laboratories (one industrial and one dermatological) with respect to critical parameter performance. The average systematic drift in sensitivity over time was 0.27% and < 1.02% for all four units tested. Difference in sensitivity between units was limited to 4.1% and was due to offset rather than gain deviation. Spatial variation in image uniformity was below 3.08% and 1.93% in the corners and centre of an individual image, respectively. This spatial variation could be further reduced to 0.25% and 0.13%, respectively by image normalization. Ambient light from a 40 W bulb or a 11 W fluorescent light source at a distance of 50-60 cm above the object, reduced the recorded values by about 10%, while the camera to object distance and image size had no detectable influence on sensitivity. Curved objects, such as human forearm, demonstrated an edge effect limited to below 10%. The critical TiVi performance parameters evaluated proved stable in relation to expected variations in skin RBCconc over time. Calibration by way of a two-point method may reduce differences in sensitivity between instruments to further facilitate inter-laboratory comparison of results.
  •  
9.
  • Pontén, Ann, et al. (author)
  • Patch testing with 2.0% (0.60 mg/cm(2) ) formaldehyde instead of 1.0% (0.30 mg/cm(2) ) detects significantly more contact allergy.
  • 2013
  • In: Contact Dermatitis. - : Wiley. - 0105-1873. ; 68:1, s. 50-53
  • Journal article (peer-reviewed)abstract
    • Background.The currently used patch test concentration for formaldehyde is 1.0% (wt/vol) in water. However, clinical experience and previous studies suggest that 1.0% might be insufficient for detecting an optimized number of clinically relevant cases of contact allergy to formaldehyde. Objectives.To validate earlier patch test results for comparison of 1% (wt/vol) and 2% (wt/vol) formaldehyde in water, and to investigate co-reactivity with quaternium-15. Materials and methods.In 12 dermatology clinics, 3591 patients were routinely patch tested simultaneously with 2.0% (wt/vol) (0.60 mg/cm(2) ) and 1.0% (wt/vol) (0.30 mg/cm(2) ) formaldehyde. Micropipettes were used for delivering the exact dosage of the allergen. Results.Significantly more patients reacted to 2.0% formaldehyde than to 1.0% (3.4% versus 1.8%, p < 0.001). Overall, there were no sex differences between those reacting positively to 2.0% and 1.0%. Of 25 quaternium-15-positive patients, 4 (0.1%) reacted positively without reacting to formaldehyde. Conclusion.On the basis of the results of this multicentre study, as well as of previous studies, it can be suggested that 2.0% (wt/vol) in water formaldehyde should be used in routine patch testing in the baseline series.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 14
Type of publication
Type of content
peer-reviewed (12)
other academic/artistic (2)
Author/Editor
Bruze, Magnus (9)
Andersen, Klaus E (7)
Goossens, An (5)
Goncalo, Margarida (5)
Isaksson, Marléne (4)
Le Coz, Christophe J ... (3)
show more...
Rustemeyer, Thomas (3)
White, Ian R. (3)
Gruvberger, Birgitta (3)
Agner, Tove (2)
Diepgen, Thomas (2)
Kelly, Daniel (1)
Bengtsson-Palme, Joh ... (1)
Nilsson, Henrik (1)
Kelly, Ryan (1)
Li, Ying (1)
Moore, Matthew D. (1)
Liu, Fang (1)
Zhang, Yao (1)
Jin, Yi (1)
Raza, Ali (1)
Rafiq, Muhammad (1)
Zhang, Kai (1)
Khatlani, T (1)
Lee, Jun Young (1)
Kahan, Thomas (1)
Sörelius, Karl, 1981 ... (1)
Batra, Jyotsna (1)
Roobol, Monique J (1)
Backman, Lars (1)
Yan, Hong (1)
Schmidt, Axel (1)
Lorkowski, Stefan (1)
Thrift, Amanda G. (1)
Zhang, Wei (1)
Hammerschmidt, Sven (1)
Patil, Chandrashekha ... (1)
Wang, Jun (1)
Pollesello, Piero (1)
Conesa, Ana (1)
El-Esawi, Mohamed A. (1)
Zhang, Weijia (1)
Li, Jian (1)
Marinello, Francesco (1)
Frilander, Mikko J. (1)
Johansen, Jeanne Duu ... (1)
Wei, Pan (1)
Badie, Christophe (1)
Zhao, Jing (1)
Li, You (1)
show less...
University
Lund University (10)
Linköping University (3)
Uppsala University (2)
Stockholm University (2)
Karolinska Institutet (2)
University of Gothenburg (1)
show more...
Halmstad University (1)
Chalmers University of Technology (1)
show less...
Language
English (14)
Research subject (UKÄ/SCB)
Medical and Health Sciences (10)
Natural sciences (1)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view