SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ohlin Acke) "

Sökning: WFRF:(Ohlin Acke)

  • Resultat 1-10 av 45
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abul-Kasim, Kasim, et al. (författare)
  • Curve length, curve form, and location of lower-end vertebra as a means of identifying the type of scoliosis.
  • 2010
  • Ingår i: Journal of Orthopaedic Surgery. - 2309-4990. ; 18:1, s. 1-5
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To determine if the curve length, curve form, and location of the lower-end vertebra can identify the type of scoliosis. METHODS: Standing posteroanterior and lateral radiographs of 78 women and 27 men with scoliosis aged 8 to 32 years were retrospectively analysed. Parameters measured were (1) the curve length (the number of vertebrae in the main curve), (2) the curve form (C-form, inverted C-form, or S-form), (3) the curve apex (the vertebral body at the apex of each curve), (4) the site of the scoliosis (thoracic, thoracolumbar, or lumbar), and (5) the location of the lower-end vertebra. RESULTS: Only 3 (4%) of 77 patients with idiopathic scoliosis had a curve length of >8 vertebrae, compared with 19 (90%) of 21 patients with neuromuscular/neuropathic scoliosis (p<0.001, Fisher's exact test). 14 (18%) of the patients with idiopathic scoliosis had an S-form curve, compared with none in those with neuromuscular/neuropathic or congenital/osteogenic scoliosis (p=0.035, Fisher's exact test). No patient with idiopathic scoliosis had the lower- end vertebra located at L5, compared with 8 (38%) patients with neuromuscular scoliosis (p<0.001, Fisher's exact test). The criteria for neuromuscular/neuropathic scoliosis (a curve length of >8 vertebrae, a C-form or inverted C-form curve, and a lower-end vertebra located at L4 or L5) had 81% specificity, 76% sensitivity, 100% positive and 93% negative predictive values. CONCLUSION: These criteria may help identify patients with neuromuscular/neuropathic scoliosis for further investigation by magnetic resonance imaging or computed tomography before they undergo corrective surgery.
  •  
2.
  • Abul-Kasim, Kasim, et al. (författare)
  • Dural ectasia in adolescent idiopathic scoliosis: quantitative assessment on magnetic resonance imaging.
  • 2010
  • Ingår i: European Spine Journal. - : Springer Science and Business Media LLC. - 0940-6719 .- 1432-0932. ; Apr 7, s. 754-759
  • Tidskriftsartikel (refereegranskat)abstract
    • To our knowledge, the assessment of dural sac diameters in patients with adolescent idiopathic scoliosis (AIS) is not reported in the literature. The aim of this study was to find out if, dural ectasia occurs more frequently among patients with AIS, to define cut-off values for dural sac ratio and test the validity of such values. A total of 126 spine MRIs (79 patients with AIS and 47 control subjects) were included in this retrospective analysis (age range 7-25 years, 62% were females). Dural sac diameter (DSD) and vertebral body diameter (VBD) were estimated and dural sac ratio (DSR = DSD/VBD) was calculated at T5 and L3. DSR at T5 and L3 were 0.69 +/- 0.12, and 0.52 +/- 0.10, respectively, in patients with AIS compared with 0.62 +/- 0.11, and 0.44 +/- 0.07, respectively, in controls (P = 0.001 at T5 and <0.001 at L3). Our estimated cut-off values for DSR were 0.84 and 0.58 at T5 and L3, respectively. This resulted in 100% sensitivity compared with 74% when using the cut-off values proposed by Oosterhof et al. No statistically significant association was found between the occurrence of dural sac enlargement in patients with AIS and the severity of scoliotic deformity, the apical vertebral rotation, epidural fat thickness, occurrence of pain, neurological deficit, atypical scoliosis or rapid curve progression. Females were affected more frequently than males. As dural sac enlargement means thinning of the pedicles, we believe that the findings of this study have important clinical implications on the preoperative workup of AIS.
  •  
3.
  •  
4.
  • Abul-Kasim, Kasim, et al. (författare)
  • Increased rod stiffness improves the degree of deformity correction by segmental pedicle screw fixation in adolescent idiopathic scoliosis.
  • 2011
  • Ingår i: Scoliosis. - : Springer Science and Business Media LLC. - 1748-7161. ; 6
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: There are limited reports in literature studying the impact of rod diameter and stiffness on the degree of deformity correction in patients with AIS. AIMS: The aims of this study were to evaluate the 3-dimentional deformity correction achieved by segmental pedicle screw fixation in patients with adolescent idiopathic scoliosis, and to find out if learning or the change to stiffer rods had any positive impact on deformity correction. STUDY DESIGN: Retrospective study. METHODS: Plain radiographs and low-dose spine CTs of 116 consecutive patients (aged 15.9 ± 2.8 years) operated during the period 2005-2009 (group 1: patients operated autumn 2005-2006; group 2: 2007; group 3: 2008; group 4: 2009) were retrospectively evaluated. RESULTS: There was no statistically significant difference between the correction of the Cobb angle (P = 0.425) or lower end vertebra tilt (P = 0.298) in patients operated during the first versus the remaining periods of the study. No restoration of the sagittal kyphosis was reported in the first period compared with 5.9° in the last study period (P < 0.001). The correction of vertebral rotation was also improved from 4.2° to 7.8° (P < 0.001) for the same periods. For the whole study population, there was statistically significant correlation between the order of the operation (patient number) and the restoration of sagittal kyphosis (r = -0.344, P = 0.001), and the correction of vertebral rotation (r = 0.370, P < 0.001), but not for the Cobb angle or LEVT. However, there was no significant difference in restoration of sagittal kyphosis and the vertebral rotation in the first 17 patients compared with the last 17 patients operated with rods of 5.5 mm diameter (P = 0.621, and 0.941, respectively), indicating that rod stiffness had more impact on the deformity correction than did learning. CONCLUSIONS: This study showed that rod stiffness had more impact on the deformity correction than did learning.
  •  
5.
  • Abul-Kasim, Kasim, et al. (författare)
  • Low-dose helical computed tomography (CT) in the perioperative workup of adolescent idiopathic scoliosis.
  • 2009
  • Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 19, s. 610-618
  • Tidskriftsartikel (refereegranskat)abstract
    • The study aims were to estimate the radiation dose in patients examined with low dose spine CT and to compare it with that received by patients undergoing standard CT for trauma of the same region, as well as to evaluate the impact of dose reduction on image quality. Radiation doses in 113 consecutive low dose spine CTs were compared with those in 127 CTs for trauma. The inter- and intraobserver agreement in measurements of pedicular width, and vertebral rotation, measurements of signal-to-noise ratio and assessment of hardware status were the indicators in the evaluation of image quality. The effective dose of the low dose spine CT (0.37 mSv) was 20 times lower than that of a standard CT for trauma (13.09 mSv). This dose reduction conveyed no impact on image quality. This low dose spine CT protocol allows detailed evaluation that is necessary for preoperative planning and postoperative evaluation.
  •  
6.
  • Abul-Kasim, Kasim, et al. (författare)
  • Measurement of vertebral rotation in adolescent idiopathic scoliosis with low-dose CT in prone position - method description and reliability analysis
  • 2010
  • Ingår i: Scoliosis. - : Springer Science and Business Media LLC. - 1748-7161. ; 5, s. 1-8
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: To our knowledge there is no report in the literature on measurements of vertebral rotation with low-dose computed tomography (CT) in prone position.Aims: To describe and test the reliability of this new method, compare it with other methods in use and evaluate the influence of body position on the degree of vertebral rotation measured by different radiological methods.Study design: Retrospective study.Methods: 25 consecutive patients with adolescent idiopathic scoliosis scheduled for surgery (17 girls, 8 boys) aged 15 ± 2 years (mean ± SD) were included in the analysis of this study. The degree of the vertebral rotation was in all patients measured according to the method of Perdriolle on standing plain radiographs and on supine CT scanogram, and according to the method of Aaro and Dahlborn on axial CT images in prone position and on magnetic resonance imaging (MRI) in supine position. The measurements were done by one neuroradiologist at two different occasions. Bland and Altman statistical approach was used in the reliability assessment.Results: The reliability of measuring vertebral rotation by axial CT images in prone position was almost perfect with an intraclass correlation coefficient of 0.95, a random error of the intraobserver differences of 2.3°, a repeatability coefficient of 3.2° and a coefficient of variation of 18.4%. Corresponding values for measurements on CT scanogram were 0.83, 5.1°, 7.2°, and 32.8%, respectively, indicating lower reliability of the latter modality and method. The degree of vertebral rotation measured on standing plain radiographs, prone CT scanogram, axial images on CT in prone position and on MRI in supine position were 25.7 ± 9.8°, 21.9 ± 8.3°, 17.4 ± 7.1°, and 16.1 ± 6.5°, respectively. The vertebral rotation measured on axial CT images in prone position was in average 7.5% larger than that measured on axial MRI in supine position.Conclusions: This study has shown that measurements of vertebral rotation in prone position were more reliable on axial CT images than on CT scanogram. The measurement of vertebral rotation on CT (corrected to the pelvic tilt) in prone position imposes lower impact of the recumbent position on the vertebral rotation than did MRI in supine position. However, the magnitude of differences is of doubtful clinical significance.
  •  
7.
  •  
8.
  • Abul-Kasim, Kasim, et al. (författare)
  • Optimization of Radiation Exposure and Image Quality of the Cone-beam O-arm Intraoperative Imaging System in Spinal Surgery.
  • 2012
  • Ingår i: Journal of Spinal Disorders and Techniques. - 1539-2465. ; 25:1, s. 52-58
  • Tidskriftsartikel (refereegranskat)abstract
    • STUDY DESIGN: Retrospective study. OBJECTIVES: To optimize the radiation doses and image quality for the cone-beam O-arm surgical imaging system in spinal surgery. SUMMARY OF BACKGROUND: Neurovascular compromise has been reported after screw misplacement during thoracic pedicle screw insertion. The use of O-arm with or without navigation system during spinal surgery has been shown to lower the rate of screw misplacement. The main drawback of such imaging surgical systems is the high radiation exposure. METHODS: Chest phantom and cadaveric pig spine were examined on the O-arm with different scan settings: 2 were recommended by the O-arm manufacturer (120 kV/320 mAs, and 120 kV/128 mAs), and 3 low-dose settings (80 kV/80 mAs, 80 kV/40 mAs, and 60 kV/40 mAs). The radiation doses were estimated by Monte Carlo calculations. Objective evaluation of image quality included interobserver agreement in the measurement of pedicular width in chest phantom and assessment of screw placement in cadaveric pig spine. RESULTS: The effective dose/cm for 120 kV/320 mAs scan was 13, 26, and 69 times higher than those delivered with 80 kV/80 mAs, 80 kV/40 mAs, and 60 kV/40 mAs scans, respectively. Images with 60 kV/40 mAs were unreliable. Images with 80 kV/80 mAs were considered reliable with good interobserver agreement when measuring the pedicular width (random error 0.38 mm and intraclass correlation coefficient 0.979) and almost perfect agreement when evaluating the screw placement (κ value 0.86). CONCLUSIONS: The radiation doses of the O-arm system can be reduced 5 to 13 times without negative impact on image quality with regard to information required for spinal surgery.
  •  
9.
  • Abul-Kasim, Kasim, et al. (författare)
  • Patients with adolescent idiopathic scoliosis of Lenke type-1 curve exhibit specific pedicle width pattern.
  • 2012
  • Ingår i: European Spine Journal. - : Springer Science and Business Media LLC. - 0940-6719 .- 1432-0932. ; 21, s. 57-63
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION: Study aim was to find out if patients with Lenke type 1 curve exhibit smaller pedicles and specific pedicle width pattern compared with individuals with no scoliosis. MATERIALS AND METHODS: 4,828 pedicle width measurements (T1-L5) in 61 consecutive patients with adolescent idiopathic scoliosis of Lenke type 1 curve, 61 control subjects, and 20 patients with Lenke type 5 curve, were retrospectively performed by an experienced neuroradiologist. RESULTS: Among patients with Lenke type 1 curve, the differences between the width of right and left upper thoracic pedicles were statistically significant; smallest at right T4 (2.6 mm). At scoliotic apex, the pedicles on the concave (left) side were significantly smaller than those on the convex (right) side; smallest at left T7 (3.2 mm). Among patients with Lenke type 1 curve, 97% had pedicle width <4 mm. CONCLUSIONS: Our study showed that patients with Lenke type 1 curve exhibit smaller pedicles and asymmetric pedicle width compared with control subjects.
  •  
10.
  • Abul-Kasim, Kasim, et al. (författare)
  • Radiation dose optimization in CT planning of corrective scoliosis surgery. A phantom study.
  • 2008
  • Ingår i: The Neuroradiology Journal. ; 21:3, s. 374-382
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the study was to explore the possibility of obtaining a helical CT scan of a long segment of vertebral column, optimally reduce the radiation dose, compare the radiation dose of the low dose helical CT with that of some of the CT protocols used in clinical practice and finally assess the impact of such a dose reduction on the image quality. A chest phantom was examined with a 16-slice CT scanner. Six scans were performed with different radiation doses. The lowest radiation dose which had no impact on image quality with regard to the information required for surgical planning of patients with scoliosis, was 20 times lower than that of routinely used protocol for CT examination of the spine in children (0.38 mSv vs 7.76 mSv). Patients with scoliosis planned for corrective spinal surgery can be examined with low dose helical CT scan. The dose reduction systems (DRS) available in modern CT scanners contribute to dose reduction and should be used.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 45
Typ av publikation
tidskriftsartikel (40)
konferensbidrag (2)
forskningsöversikt (2)
doktorsavhandling (1)
Typ av innehåll
refereegranskat (43)
övrigt vetenskapligt/konstnärligt (2)
Författare/redaktör
Ohlin, Acke (44)
Abul-Kasim, Kasim (19)
Hasserius, Ralph (14)
Karlsson, Magnus (12)
Gerdhem, Paul (6)
Maly, Pavel (5)
visa fler...
Gunnarsson, Mikael (5)
Sundgren, Pia (4)
Selariu, Eufrozina (4)
Karlsson, Magnus K. (4)
Danielsson, Aina, 19 ... (4)
Möller, Anders (4)
Overgaard, Angelica (3)
Söderberg, Marcus (3)
Besjakov, Jack (3)
Redlund-Johnell, Ing ... (3)
Strömbeck, Anita (2)
Kherad, Mehrsa (2)
Möller, Hans (1)
Hedlund, Rune (1)
Persson, Erik (1)
Mörgelin, Matthias (1)
Riesbeck, Kristian (1)
Einarsdottir, E (1)
Kere, J (1)
Andersen, M (1)
Tengvall, Pentti (1)
Strombeck, Anita (1)
Schlenzka, Dietrich (1)
Levinsson, Anders (1)
Kere, Juha (1)
Johnell, Olof (1)
Stark, André (1)
Strömblad, Lars-Göra ... (1)
Diarbakerli, Elias (1)
Gerdhem, P (1)
Dahlman, Ingrid (1)
Lerner, Ulf H (1)
Lundberg, Pernilla (1)
Fritzell, Peter (1)
Karlsson, Caroline (1)
Düppe, Henrik (1)
Anderberg, Leif (1)
Annertz, Mårten (1)
Hildingsson, Christe ... (1)
Karlberg, Mikael (1)
Lind, Bengt (1)
Olerud, Claes (1)
Andersson, Martin K (1)
Perry, Mark J (1)
visa färre...
Lärosäte
Lunds universitet (44)
Göteborgs universitet (6)
Karolinska Institutet (6)
Linköpings universitet (4)
Uppsala universitet (2)
Umeå universitet (1)
visa fler...
Malmö universitet (1)
visa färre...
Språk
Engelska (41)
Svenska (4)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (45)
Naturvetenskap (1)
Teknik (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy