SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Andreasson Håkan) srt2:(2000-2004);srt2:(2004)"

Sökning: WFRF:(Andreasson Håkan) > (2000-2004) > (2004)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  • Jensen, Eva, et al. (författare)
  • Changes in hemostasis during pediatric heart surgery: impact of a biocompatible heparin-coated perfusion system.
  • 2004
  • Ingår i: The Annals of thoracic surgery. - : Elsevier BV. - 0003-4975. ; 77:3, s. 962-7
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: This study describes the response in hemostasis during open-heart surgery with cardiopulmonary bypass (CPB) in children (<== 10 kg) and tests the hypothesis that the use of a biocompatible perfusion system, in comparison with a conventional system, causes less hemostatic activation. METHODS: Prospective, randomized, controlled clinical study. Forty consecutive children <== 10 kg were included and divided into two groups: group bioc. (n = 19) treated with a fully heparin-coated system, centrifugal pump, and a closed circuit, and group conv. (n = 21) treated with an uncoated system, roller pump, and a hard shell venous reservoir. Concentrations of plasma thrombin-antithrombin (TAT), D-dimer, tissue plasminogen activator antigen (t-PA ag), and the complex consisting of tissue plasminogen activator and its inhibitor plasminogen activator inhibitor-1 (t-PA-PAI-1) were measured. RESULTS: The biochemical variables measured increased significantly in both groups during the study period. There was less activation of fibrinolysis during cardiopulmonary bypass (t-PA ag: p = 0.009) in patients treated with the biocompatible perfusion system than in patients treated with the conventional system. A trend in favor of the biocompatible system based on the D-dimer and TAT data (p = 0.07 for both measurements) was observed but no significant intergroup differences regarding these variables or t-PA-PAI-1 were found. CONCLUSIONS: Open-heart surgery with cardiopulmonary bypass in children (<== 10 kg) causes transient activation of the coagulation and fibrinolytic systems. This study demonstrates that the use of a biocompatible perfusion system results in a lower extent of activation of fibrinolysis during CPB than the use of a conventional system.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy