Holm, Stefan H. (författare)
Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Fasta tillståndets fysik,Fysiska institutionen,Institutioner vid LTH,Other operations, LTH,Faculty of Engineering, LTH,Solid State Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Beech, Jason P. (författare)
Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Fasta tillståndets fysik,Fysiska institutionen,Institutioner vid LTH,Other operations, LTH,Faculty of Engineering, LTH,Solid State Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Barrett, Michael P. (författare)
University of Glasgow
visa fler...
Tegenfeldt, Jonas O. (författare)
University of Gothenburg,Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Fasta tillståndets fysik,Fysiska institutionen,Institutioner vid LTH,Other operations, LTH,Faculty of Engineering, LTH,Solid State Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2012
2012
Engelska 3 s.
Ingår i: Proceedings of the 16th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2012. - 9780979806452 ; , s. 530-532
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • We present a simple and rapid microfluidic device capable of extracting and concentrating the parasite causing the fatal disease sleeping sickness (SS) from blood. The device is based on deterministic lateral displacement (DLD) and constructed with a single inlet with flow induced by an ordinary syringe. The simplicity is crucial as the device is intended for use in the resource depraved areas where the disease is endemic. With only one inlet an intricate design with multiple depths has been utilized to create a cell free stream from the blood plasma into which the parasites are forced and subsequently collected in a detection region. In order to maximize the sample volume up to 10 device layers were stacked on top of each other which resulted in a throughput of ∼10 μL/min. This allowed for an approximate time per test of below 15 min.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)

Nyckelord

Deterministic lateral displacement
High-throughput
Multilayered
Point-of-care
Separation science
Shape sorting

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy