SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:hh-24132"
 

Sökning: onr:"swepub:oai:DiVA.org:hh-24132" > Optimisation and va...

Optimisation and validation of an automated solid phase extraction technique coupled on-line to enzyme-based biosensor detection for the determination of phenolic compounds in surface water samples

Burestedt, E. (författare)
Department of Analytical Chemistry, University of Lund, Lund, Sweden
Emnéus, J. (författare)
Department of Analytical Chemistry, University of Lund, Lund, Sweden
Gorton, L. (författare)
Department of Analytical Chemistry, University of Lund, Lund, Sweden
visa fler...
Marko-Varga, G. (författare)
Department of Analytical Chemistry, University of Lund, Lund, Sweden
Domínguez, E. (författare)
Department of Analytical Chemistry, Faculty of Pharmacy, University of Alcalá de Henares, Alcalá de Henares, Spain
Ortega, F. (författare)
Department of Analytical Chemistry, Faculty of Pharmacy, University of Alcalá de Henares, Alcalá de Henares, Spain
Narváez, A. (författare)
Department of Analytical Chemistry, Faculty of Pharmacy, University of Alcalá de Henares, Alcalá de Henares, Spain
Irth, H. (författare)
Division of Analytical Chemistry, Leiden/Amsterdam Center for Drug Research, Leiden, The Netherlands
Lutz, Mareike, 1967- (författare)
Division of Analytical Chemistry, Leiden/Amsterdam Center for Drug Research, Leiden, The Netherlands
Puig, D. (författare)
Department of Environmental Chemistry, CID-CSIC, Barcelona, Spain
Barceló, D. (författare)
Department of Environmental Chemistry, CID-CSIC, Barcelona, Spain
visa färre...
 (creator_code:org_t)
Heidelberg : Springer Berlin/Heidelberg, 1995
1995
Engelska.
Ingår i: Chromatographia. - Heidelberg : Springer Berlin/Heidelberg. - 0009-5893 .- 1612-1112. ; 41:3-4, s. 207-215
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A fully integrated screening system for phenolic compounds was developed incorporating on-line solid phase extraction, fractionation and biosensor detection. Two different types of biosensors, solid graphite and carbon paste electrodes incorporating the enzyme tyrosinase, were compared and used in the screening system. Interfacing of the solid phase extraction and fractionation with the biosensor detection was given special attention since the biosensors were not compatible with the organic modifier used for desorption of phenols from the solid phase extraction step. The system was validated with conventional analytical techniques. Surface water samples from the Ebro river were spiked with 1,10, and 25μg L−1 of catechol, phenol,p-cresol, respectively. Three out of seven samples were spiked and the correct samples were identified, containing phenols equivalent to the spiked concentrations. © 1995 Friedr. Vieweg & Sohn Verlagsgesellschaft mbH.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

Column liquid chromatography
Solid phase extraction
Enzyme-based biosensor detection
Tyrosinase
Phenols

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy