Visualization of multimodal polymer-shelled contrast agents using ultrasound contrast sequences : an experimental study in a tissue mimicking flow phantom

Larsson, Malin (författare)
Karolinska Institutet,KTH,Medicinsk teknik,KTH, Medicinsk teknik
Larsson, Matilda (författare)
KTH,Medicinsk teknik,KTH, Medicinsk teknik
Oddo, Letizia (författare)
visa fler...
Margheritelli, Silvia (författare)
Paradossi, Gaio (författare)
Nowak, Jacek (författare)
Karolinska Institutet
Brodin, Lars-Åke (författare)
KTH,Medicinsk teknik,KTH, Medicinsk teknik
Caidahl, Kenneth (författare)
Karolinska Institutet
Bjällmark, Anna (författare)
Karolinska Institutet,KTH,Medicinsk teknik,KTH, Medicinsk teknik
visa färre...
 (creator_code:org_t)
2013-08-29
2013
Engelska.
Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 11, s. 33-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: A multimodal polymer-shelled contrast agent (CA) with target specific potential was recently developed and tested for its acoustic properties in a single element transducer setup. Since the developed polymeric CA has different chemical composition than the commercially available CAs, there is an interest to study its acoustic response when using clinical ultrasound systems. The aim of this study was therefore to investigate the acoustic response by studying the visualization capability and shadowing effect of three polymer-shelled CAs when using optimized sequences for contrast imaging. Methods: The acoustic response of three types of the multimodal CA was evaluated in a tissue mimicking flow phantom setup by measuring contrast to tissue ratio (CTR) and acoustic shadowing using five image sequences optimized for contrast imaging. The measurements were performed over a mechanical index (MI) range of 0.2-1.2 at three CA concentrations (10(6), 10(5), 10(4) microbubbles/ml). Results: The CTR-values were found to vary with the applied contrast sequence, MI and CA. The highest CTR-values were obtained when a contrast sequence optimized for higher MI imaging was used. At a CA concentration of 106 microbubbles/ml, acoustic shadowing was observed for all contrast sequences and CAs. Conclusions: The CAs showed the potential to enhance ultrasound images generated by available contrast sequences. A CA concentration of 106 MBs/ml implies a non-linear relation between MB concentration and image intensity.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

Acoustic shadowing
Contrast agent
Contrast sequences
Contrast to tissue ratio
Flow phantom
Multimodal

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy