SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

L773:1476 5640
 

Sökning: L773:1476 5640 > (2015-2019) > Evaluation of the w...

Evaluation of the wrist-worn ActiGraph wGT3x-BT for estimating activity energy expenditure in preschool children

Delisle Nyström, C. (författare)
Karolinska Institutet
Pomeroy, J. (författare)
Marshfield Clin Research Institute, WI USA
Henriksson, P. (författare)
Karolinska Institutet
visa fler...
Forsum, Elisabet (författare)
Linköpings universitet,Avdelningen för Kirurgi, Ortopedi och Onkologi,Medicinska fakulteten
Ortega, F. B. (författare)
Karolinska Institutet
Maddison, R. (författare)
Deakin University, Australia
Migueles, J. H. (författare)
University of Granada, Spain
Löf, M. (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2017-07-26
2017
Engelska.
Ingår i: European Journal of Clinical Nutrition. - : NATURE PUBLISHING GROUP. - 0954-3007 .- 1476-5640. ; 71:10, s. 1212-1217
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND/OBJECTIVES: Easy-to-use and accurate methods to assess free-living activity energy expenditure (AEE) in preschool children are required. The aims of this study in healthy preschool children were to (a) evaluate the ability of the wrist-worn ActiGraph wGT3x-BT to predict free-living AEE and (b) assess wear compliance using a 7-day, 24-h protocol. SUBJECTS/METHODS: Participants were 40 Swedish children (5.5 +/- 0.2 years) in the Mobile-based intervention intended to stop obesity in preschoolers (MINISTOP) obesity prevention trial. Total energy expenditure (TEE) was assessed using the doubly labeled water method during 14 days. AEE was calculated as (TEEx0.9) minus predicted basal metabolic rate. The ActiGraph accelerometer was worn on the wrist for 7 days and outputs used were mean of the daily and awake filtered vector magnitude (mean VM total and mean VM waking). RESULTS: The ActiGraph was worn for 7 (n = 34, 85%), 6 (n = 4, 10%), 5 (n = 1, 2.5%) and 4 (n = 1, 2.5%) days (a valid day was. 600 awake minutes). Alone, mean VM total and mean VM waking were able to explain 14% (P = 0.009) and 24% (P = 0.001) of the variation in AEE, respectively. By incorporating fat and fat-free mass in the models 58% (mean VM total) and 62% (mean VM waking) in the variation of AEE was explained (P amp;lt; 0.001). CONCLUSIONS: The wrist-worn ActiGraph wGT3x-BT in combination with body composition variables explained up to the 62% of the variation in AEE. Given the high wear compliance, the wrist-worn ActiGraph has the potential to provide useful information in studies where physical activity in preschool children is measured.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Pediatrik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Pediatrics (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy