Intra- and inter-tester reliability and reference values for isometric neck strength

Peolsson, Anneli (författare)
Linköpings universitet,Sjukgymnastik,Hälsouniversitetet
Öberg, Birgitta (författare)
Linköpings universitet,Sjukgymnastik,Hälsouniversitetet
Hedlund, Rune (författare)
Karolinska Institute, Stockholm, Sweden
 (creator_code:org_t)
2006
2001
Engelska.
Ingår i: Physiotherapy Research International. - : Wiley. - 1358-2267 .- 1471-2865. ; 6:1, s. 15-26
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND AND PURPOSE: Age- and sex-specific reference values for neck strength based on reliable measurements in the upright position are lacking. The aim of the present study was to determine intra- and inter-tester reliability and age- and sex-specific reference values for isometric neck strength in extension, flexion and lateral flexion in sitting position measured with the David Back Clinic 140 (DBC 140) equipment.METHOD: The reliability of the DBC 140 equipment was investigated in 30 healthy volunteers and reference values were obtained from 101 healthy men and women.RESULTS: The reliability study showed that neck strength measured with the DBC 140 equipment has almost perfect intra- and inter-tester reliability (ICC values between 0.85 and 0.97). The mean value of the first in a series of three measurements was the highest for all three test leaders and for almost all directions. Results from the reference value study showed that gender is a much more important determinant of neck strength than age, body weight or body mass index (BMI). Neck strength in women was, on average, 55% of that in men, and when adjusted for body weight or BMI, the percentages were 70% and 59%, respectively. In all directions observed, neck strength decreased by approximately 20% from age 25 to 64 years.CONCLUSIONS: Measurements of neck strength taken in upright position with the DBC 140 equipment have almost perfect intra- and inter-tester reliability and justify the use of this test procedure. The use of the first measurement in a test series can be recommended for use in clinical practice since it was shown to be the maximal test value and thus, had a very low intra-tester difference. The use of reference values for neck strength when evaluating patients with neck disorders needs to take gender into account.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Peolsson, Anneli
Öberg, Birgitta
Hedlund, Rune
Artiklar i publikationen
Physiotherapy Re ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy