SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Fröling Morgan 1966 )
 

Sökning: WFRF:(Fröling Morgan 1966 ) > Nair Gireesh > Heated atrium in mu...

  • Danielski, ItaiMittuniversitetet,Avdelningen för ekoteknik och hållbart byggande,Ekoteknik; Ecotechnology (författare)

Heated atrium in multi-storey apartment buildings, a design with potential to enhance energy efficiency and to facilitate social interactions

  • Artikel/kapitelEngelska2016

Förlag, utgivningsår, omfång ...

  • Elsevier,2016
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:miun-28486
  • https://urn.kb.se/resolve?urn=urn:nbn:se:miun:diva-28486URI
  • https://doi.org/10.1016/j.buildenv.2016.06.038DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-123954URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • The design concept of conditioned atria gains increasing popularity in commercial and service buildings all over the world, but is still not a common building design in the residential sector. This study investigates the potential of such design in residential buildings in Nordic climates as means to enhance both energy efficiency as well as social interaction among residents. Energy modelling was used to compare energy efficiency among designs of residential buildings with and without atrium and to identify important design parameters. Social interaction was analysed, based on a survey evaluating the perception of residents living in an existing multi-storey apartment building designed with a heated atrium in the north of Sweden.The results show that heated atrium in Nordic climates have a potential to reduce the total final energy demand while at the same time increase the conditioned space of the building. To positively impact energy efficiency, the atrium should fulfil three requirements: (i) it should be designed to reduce the shape factor for the whole building; (ii) it should have the minimum glazed area that comply with the building requirements concerning natural light and visual comfort; and (iii) adjustable solar shading should be installed in the atrium’s façades to avoid unwanted overheating. The survey results indicate that the additional space created by the atrium has a potential to facilitate and promote social interaction among residents and to increases a sense of neighbourliness and belongingness, which are often discussed as important parameters in relation to social sustainability.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Nair, GireeshUmeå universitet,Institutionen för tillämpad fysik och elektronik,Umeå University, Department of Applied Physics and Electronics, Sweden(Swepub:umu)gigo0003 (författare)
  • Joelsson, AnnaSWECO AB (publ), Umeå, Sweden (författare)
  • Fröling, Morgan,1966-Mittuniversitetet,Avdelningen för ekoteknik och hållbart byggande,Ekoteknik; Ecotechnology(Swepub:miun)morfro (författare)
  • MittuniversitetetAvdelningen för ekoteknik och hållbart byggande (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Building and Environment: Elsevier106, s. 352-3640360-13231873-684X

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy