SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sörensen Jens)
 

Sökning: WFRF:(Sörensen Jens) > Laparoscopic extend...

Laparoscopic extended pelvic lymph node (LN) dissection as validation of the performance of [(11) C]-acetate positron emission tomography/computer tomography in the detection of LN metastasis in intermediate- and high-risk prostate cancer

Daouacher, Georgios, 1978- (författare)
Department of Urology, Central Hospital of Karlstad, Karlstad, Sweden
von Below, Catrin (författare)
Uppsala universitet,Radiologi
Gestblom, Charlotta (författare)
Department of Pathology, Central Hospital of Karlstad, Karlstad, Sweden
visa fler...
Ahlström, Håkan (författare)
Uppsala universitet,Radiologi
Grzegorek, Rafael (författare)
Department of Urology, Central Hospital of Karlstad, Karlstad, Sweden
Wassberg, Cecilia (författare)
Uppsala universitet,Radiologi
Sörensen, Jens (författare)
Uppsala universitet,Radiologi
Waldén, Mauritz (författare)
Department of Urology, Central Hospital of Karlstad, Karlstad, SwedenDepartment of Urology, Central Hospital of Karlstad, Karlstad, Sweden
visa färre...
 (creator_code:org_t)
2015-07-20
2016
Engelska.
Ingår i: BJU International. - : Blackwell Publishing. - 1464-4096 .- 1464-410X. ; 118:1, s. 77-83
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVES: To evaluate the accuracy of the radiopharmaceutical [(11) C]-acetate combined with positron emission tomography/computer tomography (acetate-PET/CT) in lymph node (LN) staging in newly diagnosed prostate cancer cases. A second aim was to evaluate the potential discriminative properties of acetate-PET/CT in clinical routine.PATIENTS AND METHODS: In a prospective comparative study, from July 2010 to June 2013, 53 men with newly histologically diagnosed intermediate- or high-risk prostate cancer underwent acetate-PET/CT investigation at one regional centre before laparoscopic extended pelvic LN dissection (ePLND) at one referral centre. The sensitivity, specificity and accuracy of acetate-PET/CT were calculated. Comparisons were made between true-positive and false-negative PET/CT cases to identify differences in the clinical parameters: PSA level, Gleason status, lymph metastasis burden and size, calculated risk of LN involvement, and curative treatment decisions.RESULTS: In all, 26 patients had surgically/histologically confirmed LN metastasis (LN+). Acetate-PET/CT was true positive in 10 patients, false positive in one, false negative in 16, and true negative in 26. The individual sensitivity was 38%, specificity 96%, and accuracy 68%. The acetate-PET/CT positive cases had significantly more involved LNs (mean 7.9 vs 2.4, P < 0.001) with larger cancer diameters (14.1 vs 4.9 mm, P = 0.001) and fewer eventually had treatment with curative intent (40% vs 94%, P <0.005), although we lack long-term outcome data.CONCLUSION: Acetate-PET/CT has too low a sensitivity for routine LN staging but the specificity is high. The acetate-PET/CT positive cases have a very high burden of LN spread.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Urology and Nephrology (hsv//eng)

Nyckelord

Laparoscopy
lymph node staging
lymph nodes
position emission tomography
prostate cancer

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy