SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lindqvist Per)
 

Sökning: WFRF:(Lindqvist Per) > RWT/SaVR-A Simple a...

RWT/SaVR-A Simple and Highly Accurate Measure Screening for Transthyretin Cardiac Amyloidosis

Arnberg, Elsa (författare)
Umeå universitet,Klinisk fysiologi
Eldhagen, Per (författare)
Karolinska Institutet
Löfbacka, Viktor (författare)
Umeå universitet,Klinisk fysiologi
visa fler...
Venkateshvaran, Ashwin (författare)
Karolinska Institutet
Pilebro, Björn (författare)
Umeå universitet,Kardiologi
Lindqvist, Per (författare)
Umeå universitet,Klinisk fysiologi
visa färre...
 (creator_code:org_t)
2022-07-15
2022
Engelska.
Ingår i: Journal of Clinical Medicine. - : MDPI. - 2077-0383. ; 11:14
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Cardiac amyloidosis is an underdiagnosed condition and simple methods for accurate diagnosis are warranted. We aimed to validate a novel, dual-modality approach to identify transthyretin cardiac amyloidosis (ATTR-CA), employing echocardiographic relative wall thickness (RWT), and ECG S-wave from aVR (SaVR), and compare its accuracy with conventional echocardiographic approaches.MATERIAL AND METHODS: We investigated 102 patients with ATTR-CA and 65 patients with left ventricular hypertrophy (LVH), all with septal thickness > 14 mm. We validated the accuracy of echocardiographic measures, including RWT, RWT/SaVR, posterior wall thickness (PWT), LV mass index (LVMI), left atrial volume index (LAVI), global longitudinal strain (GLS), and relative apical sparing (RELAPS) to identify ATTR-CA diagnosed using DPD-scintigraphy or abdominal fat biopsy.RESULTS: PWT, RWT, RELAPS, troponin, and RWT/SaVR were significantly higher in ATTR-CA compared to LVH. RWT/SaVR > 0.7 was the most accurate parameter to identify ATTR-CA (sensitivity 97%, specificity 90% and accuracy 91%). RELAPS was found to have much less accuracy (sensitivity 74%, specificity 76% and accuracy 73%).CONCLUSION: We can confirm the very strong diagnostic accuracy of RWT/SaVR to identify ATTR-CA in patients with septal thickness > 14 mm. Given its high sensitivity and specificity, RWT/SaVR > 0.7 has the potential to implement as a non-invasive, simple, and widely available diagnostic tool when screening for ATTR-CA.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

ECG
cardiac amyloidosis
left ventricular hypertrophy
relative wall thickness
transthyretin

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy