SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Cilio Corrado)
 

Sökning: WFRF:(Cilio Corrado) > Critical parameters...

Critical parameters in blood processing for T-cell assays: Validation on ELISpot and tetramer platforms

Afonso, Georgia (författare)
Scotto, Matthieu (författare)
Renand, Amedee (författare)
visa fler...
Arvastsson, Jeanette (författare)
Lund University,Lunds universitet,Diabetes - immunovirologi,Forskargrupper vid Lunds universitet,Diabetes - Immunovirology,Lund University Research Groups
Vassilieff, Dominique (författare)
Cilio, Corrado (författare)
Lund University,Lunds universitet,Diabetes - immunovirologi,Forskargrupper vid Lunds universitet,Diabetes - Immunovirology,Lund University Research Groups
Mallone, Roberto (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2010
2010
Engelska.
Ingår i: Journal of Immunological Methods. - : Elsevier BV. - 1872-7905 .- 0022-1759. ; 359:1-2, s. 28-36
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Assays detecting antigen (Ag)-specific T-cell responses in immune-mediated processes are increasingly employed to understand disease pathogenesis and "immune staging". The quantity and quality of starting peripheral blood mononuclear cell (PBMC) preparations are important factors in the performance of such assays. We therefore compared final PBMC yield and function by modifying parameters at the blood drawing, storage and processing steps. While drawing blood in vacuum-driven tubes or syringes and separating PBMCs on density gradients using standard or membrane (Leucosep (R)) tubes made no difference, storing tubes for 18 h without any agitation led to PBMC preparations contaminated with granulocytes and decreased interferon (IFN)-gamma enzyme-linked immunospot (ELISpot) responses. Even agitated blood showed a trend towards reduced ELISpot responses and increased human leukocyte Ag (HLA) multimer readouts when stored for 18 h compared to 3 h. These changes were reduced by diluting blood prior to storage. Washing PBMCs with media containing 10% human serum increased PBMC yields by 40.5%, without affecting ELISpot responses and multimer counts. However, washes with >10% human serum decreased multimer counts, with no additional improvement in PBMC yields. These findings may be relevant for optimizing and harmonizing PBMC processing procedures for T-cell assays. (C) 2010 Elsevier B.V. All rights reserved.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Immunologi inom det medicinska området (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Immunology in the medical area (hsv//eng)

Nyckelord

ELISpot
Peripheral blood mononuclear cells
T cell
Tetramer

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy