SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Larsson Rolf)
 

Sökning: WFRF:(Larsson Rolf) > (2005-2009) > Effects on blood co...

  • Christensen, KjeldUppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi (författare)

Effects on blood compatibility in vitro by combining a direct P2Y(12) receptor inhibitor and heparin coating of stents

  • Artikel/kapitelEngelska2006

Förlag, utgivningsår, omfång ...

  • 2009-07-07
  • Informa UK Limited,2006
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-95970
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-95970URI
  • https://doi.org/10.1080/09537100600746557DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • The effect of the direct platelet P2Y12 receptor inhibitor, AR-C69931MX, on activation of blood induced by stents with and without heparin coating was investigated using a whole blood Chandler loop model in vitro . Stents were deployed in Chandler loops. Fresh human blood with heparin and AR-C69931MX was rotated for 1 h at 37°C and used for measurements of platelets, microparticles, thrombin-antithrombin complex (TAT), fibrinogen binding to platelets, P-selectin expression by platelets, CD11b, Prothrombin Fragment F1+2, FXIa-AT, FXIIa-AT, C3a, sC5b-9 and stent score. In the first experiment there were four study groups with unmodified stents: 1a, no AR-C69931MX; 1b, 250 nmol/L; 1c, 750 nmol/L; 1d, 2250 nmol/L of AR-C69931MX. In the second experiment the concentration of AR-C69931MX was 500 nmol/L: 2a; tubings without stent; 2b; tubings with heparin-coated stent; 2c; tubings with unmodified stents. Heparin-coated stents were used in the third experiment: 3a; no AR-C69931MX; 3b; 500 nmol/L of AR-C69931MX. In the first experiment there were significant differences in all parameters analysed except for C3a, and stent score when the group with no AR-C69931MX was compared to all the groups with AR-C69931MX. In the second experiment there were significant differences in platelet count, TAT, FXIa-AT, FXIIa-AT and stent score when unmodified stents were compared to loops with no stents and partly to loops with heparin-coated stents. In the third experiment there was a significant reduction in generation of TAT, stent score and better preservation of platelet number by combining the platelet inhibitor and heparin-coated stents as compared to heparin-coated stents alone. The conclusion is that the direct P2Y12 receptor inhibitor AR-C69931MX reduced the different aspects of activation of blood induced by both unmodified and heparin-coated stents.

Ämnesord och genrebeteckningar

  • Heparin coating
  • Platelets
  • Purin receptor blockade
  • Stents
  • MEDICINE
  • MEDICIN

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Larsson, RolfUppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi(Swepub:uu)rolflars (författare)
  • Emanuelsson, Håkan (författare)
  • Elgue, GracielaUppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi(Swepub:uu)gracelgu (författare)
  • Larsson, AndersUppsala universitet,Institutionen för medicinska vetenskaper,Biokemisk struktur och funktion(Swepub:uu)andlarss (författare)
  • Uppsala universitetInstitutionen för onkologi, radiologi och klinisk immunologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Platelets: Informa UK Limited17:5, s. 318-3270953-71041369-1635

Internetlänk

Hitta via bibliotek

  • Platelets (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy