SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Nygren Peter)
 

Sökning: WFRF:(Nygren Peter) > (2005-2009) > Determination of pl...

Determination of platinum in human subcellular microsamples by inductively coupled plasma mass spectrometry

Björn, Erik (författare)
Umeå universitet,Kemiska institutionen
Nygren, Yvonne (författare)
Umeå universitet,Kemiska institutionen
Nhu Nguyen, Tam Trinh Thi (författare)
Umeå universitet,Kemiska institutionen
visa fler...
Ericson, Christer (författare)
Umeå universitet,Kemiska institutionen
Nöjd, Mikael (författare)
Kirurgi
Naredi, Peter (författare)
Kirurgi
visa färre...
 (creator_code:org_t)
Elsevier BV, 2007
2007
Engelska.
Ingår i: Analytical Biochemistry. - : Elsevier BV. - 0003-2697. ; 363, s. 135-42
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A fast and robust method for the determination of platinum in human subcellular microsamples by inductively coupled plasma mass spectrometry was developed, characterized, and validated. Samples of isolated DNA and exosome fractions from human ovarian (2008) and melanoma (T289) cancer cell lines were used. To keep the sample consumption to approximately 10 μl and obtain a high robustness of the system, a flow injection sample introduction system with a 4.6-μl sample loop was used in combination with a conventional pneumatic nebulizer and a spray chamber. The system was optimized with respect to signal/noise ratio using a multivariate experimental design. The system proved to be well suited for routine analysis of large sample series, and several hundreds of samples could be analyzed without maintenance or downtime. The detection limit of the method was 0.12 pg (26 pg/g) platinum. To avoid systematic errors from nonspectral interferences, it was necessary to use reagent matched calibration standards or isotope dilution analysis. An uncertainty budget was constructed to estimate the total expanded uncertainty of the method, giving a quantification limit of 2.3 pg (0.5 ng/g) platinum in DNA samples. The uncertainty was sufficiently low to study quantitative differences in the formation of Pt–DNA adducts after treatment with cisplatin using different exposure times and concentrations.

Nyckelord

Platinum; Cisplatin; ICPMS; Human subcellular microsamples; DNA; Exosomes

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy