SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Båth Magnus 1974 )
 

Sökning: WFRF:(Båth Magnus 1974 ) > Computer-aided dete...

Computer-aided detection (CAD) as a second reader using perspective filet view at CT colonography: effect on performance of inexperienced readers.

Fisichella, Valeria A, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
Jäderling, Fredrik (författare)
Horvath, Szerena (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa fler...
Stotzer, Per-Ove, 1958 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin,Institute of Medicine, Department of Internal Medicine
Kilander, Anders, 1945 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin,Institute of Medicine, Department of Internal Medicine
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Hellström, Mikael, 1950 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
visa färre...
 (creator_code:org_t)
Elsevier BV, 2009
2009
Engelska.
Ingår i: Clinical Radiology. - : Elsevier BV. - 1365-229X .- 0009-9260. ; 64:10, s. 972-82
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • AIM: To evaluate whether computer-aided detection (CAD) as a second reader using perspective filet view [three-dimensional (3D) filet] improves the performance of inexperienced readers at computed tomography colonography (CTC) compared with unassisted 3D filet and unassisted two-dimensional (2D) CTC. MATERIAL AND METHODS: Fifty symptomatic patients underwent CTC and same-day colonoscopy with segmental unblinding. Two inexperienced readers read the CTC studies on 3D filet and 2D several weeks apart. Four months later, readers re-read the cases only evaluating CAD marks using 3D filet. Suspicious CAD marks not previously described on 3D filet were recorded. Jackknife free-response receiver operating characteristic (JAFROC-1) analysis was used to compare the observers' performances in detecting lesions with 3D filet, 2D and 3D filet with CAD. RESULTS: One hundred and three lesions > or =3mm were detected at colonoscopy with segmental unblinding. CAD alone had a sensitivity of 73% (75/103) at a mean false-positive rate per patient of 12.8 in supine and 11.4 in prone. For inexperienced readers sensitivities with 3D filet with CAD were 58% (60/103) and 48% (50/103) with an improvement of 14-16 percentage points (p<0.05) compared with 2D and of 10-11 percentage points (p<0.05) compared with 3D filet. For inexperienced readers, the false-positive rate was 25-41% and 71-200% higher with 3D filet with CAD compared with 3D filet and 2D, respectively. JAFROC-1 analysis showed no significant differences in per-lesion overall performance among reading modes (p=0.8). CONCLUSION: CAD applied as a second reader using 3D filet increased both sensitivity and the number of false positives by inexperienced readers compared with 3D filet and 2D, thus not improving overall performance, i.e., the ability to distinguish between lesions and non-lesions.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Colon
Radiography
Colonography
Computed Tomographic
methods
statistics & numerical data
Colonoscopy
methods
Female
Humans
Imaging
Three-Dimensional
methods
Male
Middle Aged
Observer Variation
Prospective Studies
ROC Curve
Radiographic Image Interpretation
Computer-Assisted
methods
Sensitivity and Specificity
Software

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy