SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

L773:1437 4331
 

Sökning: L773:1437 4331 > Methodological cons...

Methodological considerations in determining sex steroids in children: comparison of conventional immunoassays with liquid chromatography-tandem mass spectrometry.

Ankarberg-Lindgren, Carina, 1963 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för pediatrik,Institute of Clinical Sciences, Department of Pediatrics
Becker, Charlotte (författare)
Svala, Emilia (författare)
visa fler...
Ryberg, Henrik, 1971 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin och klinisk nutrition,Centre for Bone and Arthritis Research,Institute of Medicine, Department of Internal Medicine and Clinical Nutrition
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: Clinical chemistry and laboratory medicine. - 1437-4331. ; 62:1, s. 85-96
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In laboratory medicine, external quality assessment (EQA) schemes have become versatile tools for detecting analytical flaws. However, EQA schemes are lacking for pediatric sex steroid levels. We aimed to investigate the suitability of different estradiol and testosterone immunoassays in a pediatric setting in comparison with clinical liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays.The study was conducted by staff and the advisory group on endocrinology at Equalis, the Swedish provider of EQA schemes for laboratory medicine. The test material consisted of five pooled serum samples from children who were either prepubertal or in puberty. Clinical laboratories enrolled in Equalis EQA schemes for estradiol and testosterone were invited to participate, as were clinical laboratories using LC-MS/MS-assays. Samples were analyzed by either routine immunoassays (n=18) or in-house LC-MS/MS assays (n=3).For estradiol, LC-MS/MS assays showed a high degree of conformity with interlaboratory coefficients of variation (CV) below 24.2%. Reported levels were between 4.9±1.2 and 33.9±1.6pmol/L (group mean±standard deviation). The direct immunoassays had lower precision; their CVs were up to 81.4%. Reported concentrations were between 25.3±18.1 and 45.7±19.4pmol/L, an overestimation compared to LC-MS/MS. Testosterone LC-MS/MS also showed a high degree of conformity, CVs were below 13.4%, and reported concentrations were from 0.06±0.00 to 1.00±0.11nmol/L. The direct immunoassays had a larger discrepancy between results; CVs were up to 95.8%. Concentrations were between 0.12±0.11 and 0.85±0.23nmol/L.For the safe diagnosis and determination of sex steroids in children, analysis with mass spectrometry-based methods is recommended.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy