SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ohlin Acke)
 

Sökning: WFRF:(Ohlin Acke) > Reliability of Low-...

Reliability of Low-Radiation Dose CT in the Assessment of Screw Placement After Posterior Scoliosis Surgery, Evaluated With a New Grading System

Abul-Kasim, Kasim (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Strombeck, Anita (författare)
Ohlin, Acke (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
visa fler...
Maly, Pavel (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Sundgren, Pia (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
2009
2009
Engelska.
Ingår i: Spine. - 0362-2436. ; 34:9, s. 941-948
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Study Design. A retrospective study. Objective. To evaluate the reliability of computed tomography (CT) with low radiation dose in the assessment of implant status in patients with adolescent idiopathic scoliosis (AIS). Summary of Background Data. The use of all-pedicle screw construct in scoliosis corrective surgery continues to gain increasing popularity since their introduction 1994 although their use in the thoracic spine carries a potential risk for neurovascular complications. CT is the method widely used to evaluate screw placement. Methods. Retrospective analysis of 46 consecutive low-dose spine CT in patients with AIS after posterior corrective surgery. Status of 809 titanium screws (642 thoracic) was evaluated. The degree of interobserver and intraobserver agreements about implant status was used as an indicator of the reliability of the low-dose spine CT in the assessment of accuracy of pedicle screw insertion. A new grading system has been developed for this purpose. Five types of misplacement have been evaluated: lateral, medial, and anterior cortical perforations; end-plate perforation; and foraminal perforation. Results. The analysis has shown a substantial interobserver and intraobserver agreements (kappa: 0.69 and 0.76, respectively) in differentiating pedicle screws with acceptable placement from screws with partial or total cortical perforation. None of the examinations was subjectively classified as unreliable. Conclusion. The study has shown that low-dose spine CT is a reliable method in evaluating screw placement in patients with AIS after posterior scoliosis surgery with titanium implants, using the here proposed grading system. The new grading system of screw misplacement was feasible and in line with the general agreement about the harmlessness of misplacement with minor pedicle breach. The reliability of low-dose spine CT in evaluation of lateral and medial cortical perforations was substantial. To reduce the radiation load, the postoperative assessment of titanium implants should be performed with low-dose CT.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

foraminal perforation
endplate perforation
perforation
medical cortical
misplacement
titanium screw
interobserver agreement

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Spine (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Abul-Kasim, Kasi ...
Strombeck, Anita
Ohlin, Acke
Maly, Pavel
Sundgren, Pia
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Spine
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy