SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Extended search

WFRF:(Jonson Björn)
 

Search: WFRF:(Jonson Björn) > Dynamic elastic pre...

Dynamic elastic pressure-volume loops in healthy pigs recorded with inspiratory and expiratory sinusoidal flow modulationRelationship to static pressure-volume loops.

Bitzén, Ulrika (author)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Drefeldt, Björn (author)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Niklason, Lisbet (author)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
show more...
Jonson, Björn (author)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
show less...
 (creator_code:org_t)
2004-02-13
2004
English.
In: Intensive Care Medicine. - : Springer Science and Business Media LLC. - 0342-4642 .- 1432-1238. ; 30:3, s. 481-488
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objective: The objective was to analyse relationships between inspiratory and expiratory static and dynamic elastic pressure-volume (P-el/V) curves in healthy pigs. Design: The modulated low flow method was developed to allow studies also of the expiratory P-el/V curves. Static P-el/V (P-el,P-st/V) and dynamic P-el/V (P-el,P-dyn/V) loops were studied in healthy pigs. Setting: Animal research laboratory in a university hospital. Material: Ten healthy anaesthetised and paralysed pigs. Interventions and measurements: A computer controlled a Servo Ventilator 900C with respect to respiratory rate, inspiratory flow and expiratory pressure to achieve a sinusoidal modulation of inspiration and expiration for determination of P-el,P-dyn/V loops from zero end-expiratory pressure (ZEEP) and from a positive end-expiratory pressure (PEEP) of 6 cmH(2)O to 20, 35 and 50 cmH(2)O. The same system was used for studies of P-el,P-st/V loops with the flow-interruption method from ZEEP and PEEP to 35 cmH(2)O. Recordings were analysed with an iterative technique. Results: The feasibility of automated determination of P-el,P-dyn/V loops was demonstrated. Differences between P-el,P-dyn/V and P-el,P-st/V loops were explained by viscoelastic behaviour. P-el,P-st/V loops recorded from PEEP to 35 cmH(2)O showed no significant hysteresis, indicating a non-significant surface tension hysteresis. P-el,P-dyn/V loops from PEEP and both P-el,P-st/V and P-el,P-dyn/V loops from ZEEP to 35 cmH(2)O showed hysteresis. This indicates that lung collapse/re-expansion caused P-el/V loop hysteresis which, in P-el,P-dyn/V loops, was augmented by viscoelastic behaviour. Conclusions: Viscoelasticity influences P-el,P-dyn/V curves. Hysteresis caused by surface tension merits re-evaluation. Lung collapse and re-expansion may be indicated by hysteresis of P-el/V loops.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)

Keyword

mechanical
respiratory mechanics
hysteresis
compliance
ventilation
swine

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Bitzén, Ulrika
Drefeldt, Björn
Niklason, Lisbet
Jonson, Björn
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Anesthesiology a ...
Articles in the publication
Intensive Care M ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view