SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

L773:0161 5505 OR L773:1535 5667
 

Sökning: L773:0161 5505 OR L773:1535 5667 > (1980-1984) > Dosimetry in lympho...

Dosimetry in lymphoscintigraphy of Tc-99m antimony sulfide colloid

Bergqvist, L. (författare)
Lund University,Lunds universitet
Strand, S. E. (författare)
Lund University,Lunds universitet
Persson, B. (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Rausinglaboratoriet i Lund - Tumörsektionen,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Rausing laboratory of Lund - Tumor section,Lund University Research Groups
visa fler...
Hafström, L. (författare)
Lund University
Jönsson, P. E. (författare)
Lund University,Lunds universitet,Kirurgi,Forskargrupper vid Lunds universitet,Surgery,Lund University Research Groups
visa färre...
 (creator_code:org_t)
1982
1982
Engelska.
Ingår i: Journal of Nuclear Medicine. - 0161-5505. ; 23:8, s. 698-705
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A quantitative kinetic technique using a scintillation camera has been developed for investigating lymph drainage and the uptake in the lymph nodes of 99mTcSb2S3 colloid injected subcutaneously. Twenty-two patients with primary malignant melanoma were examined. Lymph-node dissection was performed and 185 lymph nodes were individually measured for radioactivity. The kinetics of colloid uptake in individual nodes can be expressed by a simple two-compartment model. The outflow of colloid from the injection site was found to be monoexponential, and the tissue volume containing the injected colloid at the injection site increased asymptotically with time. A model has been developed for calculating absorbed doses at the injection site and in organs with colloid uptake. The following absorbed doses were estimated (μGy/MBq): whole body 0.7-4.5, gonads 0-22, liver 1.0-3.9, lymph nodes up to 1000 and injection site about 10,000. Possible biological effects in the skin and effective dose equivalents have been estimated when using other lymphoscintiscanning agents.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bergqvist, L.
Strand, S. E.
Persson, B.
Hafström, L.
Jönsson, P. E.
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Journal of Nucle ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy