SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

L773:1530 437X OR L773:1558 1748
 

Sökning: L773:1530 437X OR L773:1558 1748 > (2005-2009) > Sberveglieri Giorgio > Metal oxide nanowir...

Metal oxide nanowire and thin-film-based gas sensors for chemical warfare simulants detection

Ponzoni, Andrea (författare)
CNR-INFM SENSOR Laboratory
Baratto, Camilla (författare)
CNR-INFM SENSOR Laboratory
Bianchi, Sebastiano (författare)
CNR-INFM SENSOR Laboratory
visa fler...
Comini, Elisabetta (författare)
CNR-INFM SENSOR Laboratory
Ferroni, Matteo (författare)
CNR-INFM SENSOR Laboratory
Pardo, Matteo (författare)
CNR-INFM SENSOR Laboratory
Vezzoli, Marco (författare)
CNR-INFM SENSOR Laboratory
Vomiero, Alberto (författare)
CNR-INFM SENSOR Laboratory
Faglia, Guido (författare)
CNR-INFM SENSOR Laboratory
Sberveglieri, Giorgio (författare)
CNR-INFM SENSOR Laboratory
visa färre...
 (creator_code:org_t)
2008
2008
Engelska.
Ingår i: IEEE Sensors Journal. - 1530-437X .- 1558-1748. ; 8:6, s. 735-742
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This work concerns with metal oxide (MOX) gas sensors based on nanowires and thin films. We focus on chemical warfare agents (CWAs) detection to compare these materials from the functional point-of-view. We work with different chemicals including simulants for Sarin nerve agents, vescicant gases, cyanide agents, and analytes such as ethanol, acetone, ammonia, and carbon monoxide that can be produced by everyday activities causing false alarms. Explorative data analysis has been used to demonstrate the different sensing performances of nanowires and thin films. Within the chosen application, our analysis reveal that the introduction of nanowires inside the array composed by thin films can improve its sensing capability. Cyanide simulants have been detected at concentrations close to 1 ppm, lower than the Immediately Dangerous for Life and Health (IDLH) value of the respective warfare agent. Higher sensitivity has been obtained to simulants for Sarin and vescicant gases, which have been detected at concentrations close or even lower than 100 ppb. Results demonstrate the suitability of the proposed array to selectively detect CWA simulants with respect to some compounds produced by everyday activities. © 2008 IEEE.

Ämnesord

NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)

Nyckelord

Chemical warfare agents (CWAs)
DMMP
Explorative data analysis
MOS devices
Nanowires
Thin films
Experimentell fysik
Experimental Physics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy