Membrane protein and peptide sample handling for MS analysis using a structured MALDI target

Redeby, Theres (författare)
KTH,Analytisk kemi
Emmer, Åsa (författare)
KTH,Analytisk kemi
 (creator_code:org_t)
2004-12-22
2005
Engelska.
Ingår i: Analytical and Bioanalytical Chemistry. - : Springer Science and Business Media LLC. - 1618-2642 .- 1618-2650. ; 381:1, s. 225-232
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Different sample handling methods for hydrophobic proteins and peptides were evaluated in association with the utilization of a structured matrix-assisted laser/desorption ionization (MALDI) target for increased sensitivity. The fluorinated organic solvent hexafluoroisopropanol (HFIP) was used for the solubilization of both the full-length protein bacteriorhodopsin (BR) and a cyanogen bromide digest thereof, and compared to the performance of the non-ionic detergents octyl-beta-D-glucopyranoside (OG), dodecyl-beta-D-maltoside (DM), and Triton X-100. A concentrating effect was seen when using the structured MALDI plate for BR dissolved in all the different detergents, of which OG generated the best-quality spectra for the full-length integral membrane protein as well as for the hydrophobic peptides. However, the uneven analyte distribution obtained with the detergent preparations required selective and thus time-consuming acquisition of spectra. When instead HFIP was used as sample solvent, a tenfold increase in sensitivity was achieved for full-length BR. Addition of acids to the HFIP-solubilized sample, or to the MALDI matrix solution, improved the signals for a few of the peptides, while degrading the spectra of others. Consequently, the addition of acid could be used as a complementary sample preparation method for hydrophobic peptides. On-target washing to remove contaminants (e.g., salt) was performed, and a recrystallization protocol for signal improvement specifically suited for hydrophobic peptides is described. Results from digestion and solubilization in different micro centrifuge tubes were examined to determine the influence of different materials on the possible sample loss due to wall adhesion. Studies of sample solution storage times suggest immediate analysis after solubilization to obtain best results.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

structured sample support
MALDI-MS
hydrophobic peptides
integral membrane proteins
sample handling
Analytical chemistry
Analytisk kemi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Redeby, Theres
Emmer, Åsa
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Analytical and B ...
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy